An Accurate Operation of Wideband Multi-Port Reflectometer with New Calibration Method implementing Least Mean Square for Microwave Imaging Application
2015
The wideband operation of multi-port reflectometer may lead to inaccurate reflection coefficient measurement caused by the overlapped phase characteristics of the used calibration standards. Therefore, a calibration procedure implementing Least Mean Square (LMS) is proposed to offer accurate operation of wideband multi-port reflectometer from 1 to 6 GHz. Its well wideband performance is verified by attenuators of 3, 6 and 10 dB that assessed as the device under tests (DUTs). The proposed LMS contains a learning rate, m and updated weight coefficient, W ( k+ 1) to eliminate error and achieve the corrected reflection coefficient of DUT.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
37
References
0
Citations
NaN
KQI