A mitochondria-targeted fluorescent probe for fast detecting hypochlorite in living cells
2020
Abstract A fast-responsive fluorescent probe PI-Py was designed and synthesized for sensitive and selective detecting hypochlorite (ClO−). The probe PI-Py was intrinsically non-fluorescent due to the PET effect of the phenothiazine moiety. After reacting with ClO−, the PET effect was blocked, and a strong green emission of the BODIPY unit was recovered. The probe PI-Py showed an excellent selectivity towards ClO− in comparison of other ROS. The limit of detection for ClO− was calculated to be 1.7 nM, proving the probe's high sensitivity. Moreover, the probe PI-Py has been proved to be effective in visualizing the variations of exogenous ClO− in living HeLa cells. A co-localization study employing Mito Tracker red reveals that the PI-Py is specifically located in the mitochondria.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
44