To determine the economic effect of light weight ceramics, several sizes of filters were cost estimated for operation at 217.5 psi (15 bar) based on the use of all light weight ceramics (Fibro/Fibro) vs. the use of cooled alloy (RA300) tubesheets and silicon carbide candles (Alloy/SiC). A jet pulse delivery system was included in both estimates. The Fibro/Fibro system was estimated with the plenum design while the Alloy/SiC system was based on header/nozzle design. Battery limits were the filters and jet pulse delivery systems, Ex-works, with no main valves or dust removal systems. It was found that the cost of Fibro/Fibro components were consistently lower than the cost of the Alloy/SiC components; this comparison is illustrated in Figure 8.