O1018 RADIATION EXPOSURE IN PERTROCHANTERIC FRACTURE FIXATION; THE DIFFERENCE BETWEEN EXTRAMEDULLARY AND INTRAMEDULLARY IMPLANT
2004
Aims: To compare the results between intramedullary hip screw (IMHS) and dynamic hip screw (DHS) regarding operative time and radiation exposure time Methods:We reviewed radiation exposure times obtained during the fixation of 281 extracapsular proximal femoral fractures. Dynamic hip screw was used in 148, and intramedullary hip screw was used in 133. Results: The results showed that there was no statistical difference in ionising radiation exposure in closed reduction of these fractures regardless of fracture configuration or surgical experience of the surgeon, but there was a statistical difference in implant insertion time and radiation exposure (p= < 0.05). Conclusions: We conclude that intramed-ullary implant takes more radiation exposure because they take more time for insertion, which is irrespective of surgical experience and complexity of fracture.