Ion chromatography for determination of nitrite and nitrate in seawater using monolithic ODS columns
2005
A fast and highly sensitive ion chromatographic method using monolithic ODS columns was developed for the determination of nitrite (NO2 − ) and nitrate (NO3 − ) in seawater. Two monolithic ODS columns (50 mm× 4.6 mm i.d. + 100 mm× 4.6 mm i.d.) connected in series were coated and equilibrated with 5 mM cetyltrimethylammonium chloride (CTAC) aqueous solution. The column efficiency with 0.5 M NaCl as the mobile phase did not decrease in spite of the increase in flow rate of the mobile phase. Thus, good chromatograms were obtained within 3 minutes for NO2 − and NO3 − in artificial seawater without interferences by coexisting ions. The detection limit (S/N = 3) with UV detection at 225 nm was 0.8 and 1.6g/L for NO2 − and NO3 − , respectively. The characteristics of the monolithic CTA + -coated ODS columns were discussed. The present method was successfully applied to the fast and sensitive determination of NO2 − and NO3 − in real seawater samples.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
24
References
84
Citations
NaN
KQI