Pulsed optically pumped atomic clock with a medium- to long-term frequency stability of 10−15
2020
Herein, we report a significant improvement in the medium- to long-term frequency stability of our pulsed optically pumped (POP) vapor-cell rubidium clock. Such an achievement is established with the better control of our system and the environment. An integrated optical module, including a distributed Bragg reflector laser and an acousto-optic modulator, is developed to improve the stability of the laser. The physics package is sealed in a vacuum chamber with a vacuum of 4 × 10−4 Pa to significantly reduce the impacts of the barometric effect. An AC-driven heater is placed much closer to the cell to enable a better temperature control. The resolution of the servo control voltage is also optimized. With all these improvements, a frequency stability of 4.7 × 10−15 at 104 s in terms of the Allan deviation is obtained. We also estimate the main noise sources that limit the frequency stability of the POP atomic clock.
Keywords:
- Correction
- Source
- Cite
- Save
- Machine Reading By IdeaReader
22
References
6
Citations
NaN
KQI