Total internal reflection microscopy

Total internal reflection microscopy is a specialized optical imaging technique for object tracking and detection utilizing the light scattered from an evanescent field in the vicinity of a dielectric interface. Its advantages are a high signal-to-noise ratio and a high spatial resolution in the vertical dimension. Total internal reflection microscopy is a specialized optical imaging technique for object tracking and detection utilizing the light scattered from an evanescent field in the vicinity of a dielectric interface. Its advantages are a high signal-to-noise ratio and a high spatial resolution in the vertical dimension. Total internal reflection of light occurs at the interface between materials of differing indices of refraction at incident angles greater than the critical angle, θ c {displaystyle heta _{c}} , where and n 1 {displaystyle n_{1}} is the index of the incident medium and n 2 {displaystyle n_{2}} the index of the transmission medium and θ c {displaystyle heta _{c}} is measured from the normal to the interface. Under conditions of total internal reflection, the electromagnetic field in the transmission medium takes on the form of an evanescent wave, whose intensity I ( z ) {displaystyle I(z)} decays exponentially with distance from the interface such that, with β = 4 π λ ( n 1 sin ⁡ ( θ ) ) 2 − n 2 2 {displaystyle eta ={frac {4pi }{lambda }}{sqrt {(n_{1}sin( heta ))^{2}-n_{2}^{2}}}} . For practical purposes, the transmission medium is often chosen to be a fluid—usually water—in which a microscopic object can be immersed. The object, when brought close to the interface, is expected to scatter light proportional to the intensity of the field at its height, z {displaystyle z} . Since the penetration depth of the evanescent field is on the order of hundreds of nanometers, this technique is among the most sensitive for tracking displacements in the direction perpendicular to a surface. The thin excitation region of an evanescent field allows for wide-field imaging of a select sample area with high signal-to-noise ratio. Rather than relying on optical scattering, however, often fluorophores are introduced into the sample for more selective visualization in biological applications. This popular imaging technique is known as a Total internal reflection fluorescence microscopy. Using a calibrated evanescent wave, the position of a colloidal particle or microscopic probe may be tracked with nanometer precision by monitoring the intensity of light scattered via frustrated total internal reflection. Detailed dynamics of the probe or particle can then be obtained, either in thermal equilibrium or non-equilibrium conditions. For instance, by collecting the time-independent position probability distribution of a probe particle in thermal equilibrium, and inverting the Maxwell–Boltzmann distribution, where Z {displaystyle Z} is the partition function, and k {displaystyle k} the Boltzmann constant, one can obtain the potential energy profile of interactions between the particle and a surface. In this manner, sub-picoNewton forces may be detected.

[ "Membrane", "Fluorescence", "Microscopy", "Total internal reflection" ]
Parent Topic
Child Topic
    No Parent Topic