To explore the feasibility of a novel computer color-matching (CCM) system based on the improved back-propagation neural network (BPNN) model by comparing it with the traditional visual method.Forty-three metal-ceramic specimens were fabricated by proportionally mixing porcelain powders. Thirty-nine specimens were randomly selected to train the BPNN model, while the remaining four specimens were used to test and calibrate the model. A CCM system based on the improved BPNN model was constructed using MATLAB software. A comparison of the novel CCM system and the traditional visual method was conducted by evaluating the color reproduction results of 10 maxillary central incisors. Metal-ceramic specimens were fabricated using two color reproduction approaches. Color distributions (L*, a*, and b*) of the target teeth and of the corresponding metal-ceramic specimens were measured using a spectroradiometer. Color differences (ΔE) and color distributions (ΔL*, Δa*, and Δb*) between the teeth and their corresponding specimens were calculated.The average ΔE value of the CCM system was 1.89 ± 0.75, which was lower than that of the visual approach (3.54 ± 1.11, p < 0.01). With respect to color distributions, substantial differences were found between the two color-matching systems, except for ΔL* (p > 0.05).The novel CCM system produced greater accuracy in color reproduction within the given color space than the traditional visual approach.
Significant research has proposed that the implant with microthread in the neck can significantly reduce marginal bone loss, but whether it is consistent in the condition of marginal bone loss is still unknown. The objective of this study is to investigate the effect of microthread on stress distribution in peri-implant bone with different bone level using finite element analysis. A series of computational models of mandible segments with different bone resorption and implant models with or without microthread in the neck was installed by computer-aided design software. The simulated occlusal force of 150N was applied buccolingually on the top center point of implant. The FEA was performed, and the von Mises stress, principal stress and shear stress in peri-implant bone were recorded and analyzed. In all models, the T-neck group exhibits higher von Mises stress and principal stress, as well as lower shear stress than S-neck group. Three types of stresses increase with the depth of bone resorption developed, but the differences of shear stress between two groups of implants were gradually decreased. The micro-thread design in implant neck can reduce marginal bone loss by decreasing shear stress in peri-implant bone, but this effect is gradually weakened with the decline of the marginal bone level.