In order to achieve a fast, high-efficiency analysis of platelet aggregation, a novel microfluidic chip was designed and fabricated based on the traditional measurement principle and method. The chip had a main channel and six branch channels, which were connected with their own inlets (outlets). The master of this chip was fabricated using the traditional photolithography methods. Polydimethylsiloxane chip was replica molded on the master. In the platelet aggregation assay, blood sample and coagulant were loaded from separate inlets on both sides of the chip. Due to the diffusion of analytes in the laminar flow, two analytes diffused and mixed with each other within the main channel and gradually aggregated. The distance from the mixing point to the aggregation point denoted the aggregation capacity of the blood sample. Compared with traditional measurement methods based on glass tubes, this microfluidic chip–based method is simple, highly efficient, rapid, low consuming, inexpensive, and has high repeatability. Furthermore, it may be made as a portable device for wide application in clinical analysis.
Atrial fibrillation (AF) is common in abdominal solid organ transplant recipients and a cause of morbidity and mortality in this population. However, the outcomes of catheter ablation (CA) in transplant recipients with AF remain unclear. This study aimed to elucidate the outcomes of CA in renal and hepatic transplant recipients.Between 2015 and 2019, 14 transplant recipients (nine with kidney transplantation and five with liver transplantation) were enrolled from among 10,741 AF patients and underwent CA at Anzhen Hospital. Another 56 patients matched by age, sex, and AF type were selected as the control group (four controls for each transplant recipient). During a mean follow-up of 30.0 ± 13.3 months after the initial procedure, 10 (71.4%) of the transplant patients, compared to 41 (73.2%) of the control patients, remained free from AF recurrence (p = 1.000). A repeated procedure was performed in one transplant patient and in six control subjects. Consequently, 11 (78.6%) of the transplant patients, compared to 46 (82.1%) of controls, were in sinus rhythm after the repeated ablation (p = .715). Notably, Kaplan-Meier analysis did not demonstrate any significant differences in the atrial arrhythmia-free rate after the initial and repeated procedure between the two groups. Vascular complications were identified in one transplant patient and two control subjects, while no life-threatening complications were observed in either group. There was no transient allograft dysfunction in transplant recipients after CA.CA is safe and effective in abdominal solid transplant recipients, and maybe an optimal therapeutic strategy for this group.
Background Symptomatic prolonged sinus pauses on termination of atrial fibrillation (AF) are an accepted indication for pacemaker implantation. We evaluated the outcome of AF ablation in patients with paroxysmal AF‐related tachycardia‐bradycardia syndrome and compared the efficacy of catheter ablation with permanent pacing plus antiarrhythmic drugs (AADs). Methods and Results Patients with prolonged symptomatic sinus pauses on termination of AF were retrospectively analyzed. Forty‐three consecutive patients who underwent catheter ablation (ABL group) were compared to 57 patients who underwent permanent pacing plus AADs (PM group). All 43 patients in the ABL group fulfilled Class I indication for pacemaker implantation at baseline but they actually underwent AF ablation. Reevaluation after 20.1 ± 9.6 months of follow‐up showed that 41 patients (95.3%) did no longer need a pacemaker (Class III indication). Total cardiac‐related rehospitalization was not significantly different between the two groups (P = 0.921). Tachycardia‐related hospitalization was significantly higher in the PM group than the ABL group (14.0% and 0%, P = 0.029). More patients in the PM group were on AADs (PM 40.4%, ABL 4.7%, P < 0.001) while sinus rhythm maintenance was remarkably higher in the ABL group at the end of follow‐up (83.7% vs 21.1% in PM group, P < 0.001). Conclusions In patients with paroxysmal AF‐related tachycardia‐bradycardia syndrome, AF ablation seems to be superior to a strategy of pacing plus AAD. Pacemaker implantation can be waived in the majority of patients after a successful ablation.
To investigate theoptimal idarucizumab (dabigatran antagonist) usage strategy for patients with acute pericardial tamponade receiving uninterrupted dabigatran during catheter ablation for atrial fibrillation (AF).Ten patients presenting acute pericardial tamponade while receiving uninterrupted dabigatran during catheter ablation for AF in Beijing Anzhen Hospital from January 2019 to July 2020 were enrolled and retrospectively analyzed. A "wait and see" strategy of idarucizumab was carried out for all patients; in brief, idarucizumab was applied following pericardiocentesis, comprehensive evaluation of bleeding and hemostasis.There were five males, five paroxysmal AF, and the average age of the patients was 64.0 ± 9.8 years. Among the 10 patients, four were treated with dabigatran 110 mg, six were treated with dabigatran 150 mg, and one was simultaneously given clopidogrel. The average time from pericardial tamponade to the last dose of dabigatran was 8.2 ± 3.4 h. All patients underwent pericardiocentesis successfully, and the average drainage volume was 322.5 ml (220.0 ± 935.0 ml). For reversal anticoagulation, six patients received protamine, and five patients received idarucizumab. Of the five patients who were treated with idarucizumab, four presented exact hemostasis, except for one patient who underwent continuous drainage and finally received surgery repair. The average time to restart anticoagulation was 1.1 ± 0.3 days after the procedure, and no rebleeding, embolism or deaths were observed.The "wait and see" strategy of idarucizumab for acute pericardial tamponade during the perioperative period of catheter ablation for AF may be safe and feasible.
Although several studies have proved that repeat catheter ablation is beneficial to recurrent atrial tachycardia (AT)/atrial fibrillation (AF) after AF catheter ablation, the hard endpoints of the effect of catheter ablation on recurrent AT/AF patients after AF catheter ablation remains unclear. Our study aims to compare the effect of catheter ablation and drug therapy on recurrent AT/AF patients after AF catheter ablation.Four thousand nine hundred and thirteen consecutive patients with recurrent AT/AF after catheter ablation from the China-AF registry were enrolled. The patients were divided into two study groups: the repeat catheter ablation group and the medical therapy group. The primary endpoint is a composite of cardiovascular mortality or ischaemic stroke or major bleeding events. Secondary endpoints were each component of the primary endpoints and AF recurrence rate. Landmark analysis and Cox regression were used in the statistical analysis. We chose landmark 36 months as the primary landmark date. Over a median follow-up period of 40 ± 24 months, 4913 patients were divided into either the repeat ablation group or the medical therapy group. The cumulative incidence of the composite primary outcome was significantly lower in the repeat ablation group than the medical therapy group (adjusted hazard ratio = 0.56; 95% confidence interval: 0.35-0.89; P = 0.015) of landmark 36 months (2359 patients were included in medical therapy group and 704 patients were included in repeat ablation group at landmark 36 months). However, all secondary endpoints were not statistically different in the two groups, including cardiovascular mortality, ischaemic stroke, major bleeding events, and AF recurrence rate.Based on this research, in recurrent AT/AF patients after a catheter ablation procedure, compared with medical therapy, repeat catheter ablation may significantly reduce the risk of the endpoint of composite cardiovascular mortality, ischaemic stroke, and major bleeding events.
Reported rates of oral anticoagulation (OAC) use have been low among Chinese patients with atrial fibrillation (AF). With improved awareness, changing guidelines, this situation may be changing over time. We aimed to explore the current status and time trends of OAC use in Beijing.We used the data set from the Chinese Atrial Fibrillation Registry (CAFR), a prospective, multicenter, hospital-based registry study involving 20 tertiary and 12 nontertiary hospitals in Beijing. A total of 11 496 patients with AF were enrolled from 2011 to 2014.Seven thousand nine hundred seventy-seven eligible patients were included in this ancillary study. The proportions of OAC use were 36.5% (2268/6210), 28.5% (333/1168), and 21.4% (128/599) for patients with CHA2DS2-VASc scores ≥2, 1, and 0, respectively. Persistent AF, history of stroke/transient ischemic attack/peripheral embolism, diabetes mellitus, higher body mass index, and tertiary hospital management were factors positively associated with OAC use, whereas older age, previous bleeding, hypercholesterolemia, and established coronary artery disease were factors negatively associated with OAC use. Among patients with CHADS2 scores ≥2 and CHA2DS2-VASc scores ≥2, the proportion of OAC use increased from 31.3% to 64.5% and 30.2% to 57.7%, respectively, from 2011 to 2014. Variation in OAC use was substantial among different hospitals.An improvement of OAC use among Chinese patients with AF in Beijing is observed in recent years although only 36.5% of patients with CHA2DS2-VASc score ≥2 received OAC. However, variations between different hospitals were large, suggesting that better education and awareness are needed to improve efforts for stroke prevention among AF patients.URL: http://www.chictr.org.cn/showproj.aspx?proj=5831. Unique identifier: ChiCTR-OCH-13003729.
This study aimed to evaluate the feasibility of real-time visualization and mapping of the right phrenic nerve (RPN) by using intracardiac echocardiography (ICE) during atrial fibrillation (AF) ablation.RPN injury is a complication associated with the ablation of AF. Multiple approaches are currently being used to prevent and detect RPN injuries. However, none of these approaches can directly visualize the RPN in real-time during the ablation procedure.The RPN was detected using ICE. The RPN and its adjacent structures were analysed. The relationship between the RPN's distance from the superior vena cava (SVC) and its pacing capture threshold was quantified. The safety of SVC isolation guided by the ICE-visualized RPN was evaluated. Thirty-eight people were enrolled in this study. The RPN was visualized by ICE in 92% of patients. It ran through the space between the SVC and the mediastinal pleura and had a 'straw'-like appearance upon ICE imaging. The course of the RPN was close to the SVC (minimum 1.0 ± 0.4 mm) and the right superior pulmonary vein (minimum 14.1 ± 7.3 mm). There was a positive linear correlation between the RPN's capture threshold and its distance from the SVC (Spearman's correlation coefficient = 0.728, < 0.001). SVC isolation was guided by the RPN; none of the patients developed an RPN injury.RPN can be visualized by ICE in most patients, thus providing a novel approach for the real-time detection of RPN during AF ablation.
Cardiac tamponade is a rare but life-threatening complication during atrial fibrillation (AF) catheter ablation. Contact force (CF)–sensing catheters improve ablation effectiveness. However, the impact of the application of CF-sensing catheters on the occurrence of cardiac tamponade remains unclear. The aim of this study is to evaluate the "real-world" impact of CF-sensing catheters on cardiac tamponade during AF ablation in an experienced medical center. This was a retrospective study of consecutive de novo AF ablation procedures at Beijing Anzhen Hospital between 2013 and 2016. The ablation procedure was divided into a CF group and a non-CF group. Logistic regression analysis was used to evaluate the association between the use of CF-sensing catheters and the risk of cardiac tamponade. A total of 5313 patients with AF were involved in this study. The incidence of cardiac tamponade in the CF group was significantly higher than that in the non-CF group (1.07% vs. 0.44%, P = 0.009). Of the cardiac tamponade cases in the non-CF group, 45.45% were delayed compared with 10% in the CF group (P = 0.011). Multivariate logistic regression analysis showed that CF-sensing catheters increased the risk of cardiac tamponade (OR = 2.34, 95% CI = 1.17–4.26, P = 0.015). Stratified analysis revealed patients with a smaller left atrium dimension, lower ejection fraction, longer procedure duration, or longer ablation duration had a greater risk of cardiac tamponade during ablation with CF-sensing catheters. CF-sensing catheters increase the risk of cardiac tamponade during AF ablation.
A left-sided accessory pathway (AP) with atrial insertion away from the mitral annulus (MA) may result in difficulty or failed ablation along the MA. We report our initial experience of ablating this rare form of AP by a 3-dimensional electroanatomical mapping system (CARTO).From January 2007 to August 2011, 29 patients with left-sided APs who failed previous ablations in other centers were enrolled in this study. Left atrium (LA) was reconstructed during orthodromic atrioventricuar reentry tachycardias (AVRTs) or ventricle pacing by using a 3-dimensional electroanatomical mapping system. The AP atrial insertion was defined as the earliest retrograde atrial activation and successful ablation of the AP at the site.Among the 29 patients who had failed previous ablation, 7 patients were found to have atrial insertions away from the MA. Out of the 7 patients, atrial insertions were at the base of the LA appendage in 5 patients and at the anterior roof of LA in 2 patients. Ablation at the atrial insertion successfully abolished AP conduction. The mean distance between the atrial insertion sites and the MA was 24.9 ± 4.9 mm. No patients reported recovered AP conduction or recurrent tachycardias after at least 12-month follow-up.Left-sided APs may have atrial insertions away from the MA. By using the CARTO system, atrial insertions can be reliably identified and ablated.