General anesthesia (GA) has been considered the anesthetic technique which most frequent leads to phantom limb pain (PLP) after a limb amputation. However, these prior reports were limited by small sample sizes. The aims of this study were to evaluate the incidence of PLP according to the various anesthetic techniques used for limb amputation and also to compare the occurrence of PLP according to amputation etiology using the Korean Health Insurance Review and Assessment Service for large-scale demographic information.The claims of patients who underwent limb amputation were reviewed by analyzing the codes used to classify standardized medical behaviors. The patients were categorized into three groups-GA, neuraxial anesthesia (NA), and peripheral nerve block (PNB)-in accordance with the anesthetic technique. The recorded diagnosis was confirmed using the diagnostic codes for PLP registered within one year after the limb amputation.Finally, 7,613 individuals were analyzed. According to the recorded diagnoses, 362 patients (4.8%) developed PLP after amputation. Among the 2,992 patients exposed to GA, 191 (6.4%) were diagnosed with PLP, whereas 121 (4.3%) of the 2,840 patients anesthetized with NA, and 50 (2.8%) of the 1,781 patients anesthetized under PNB developed PLP. The relative risks were 0.67 (95% confidence interval [CI], 0.53-0.84; P< 0.001) for NA and 0.43 (95% CI, 0.32-0.59; P< 0.001) for PNB.In this retrospective cohort study, using large-scale population-based databases, the incidence rates of PLP after limb amputations were, in the order of frequency, GA, NA, and PNB.
BACKGROUND Catheter-related bladder discomfort (CRBD) is problematic in patients with a urinary catheter. Transcutaneous electrical nerve stimulation (TENS) is a non-invasive analgesic modality used to relieve various types of pain. OBJECTIVES We evaluated the effect of TENS on CRBD after transurethral resection of bladder tumours (TURBT). DESIGN A randomised controlled trial. SETTING A large university tertiary hospital, from October 2022 to March 2023. PATIENTS Patients requiring urinary catheterisation after TURBT. INTERVENTION In this randomised controlled trial, patients were randomly allocated to the TENS ( n = 56) or control ( n = 56) groups. CRBD manifests as a burning sensation with an urge to void or discomfort in the suprapubic area. Moderate to severe CRBD was defined as patients self-reporting CRBD symptoms with or without behavioural response, including attempts to remove the urinary catheter, intense verbal reactions, and flailing limbs. TENS was performed from the end of surgery to 1 h postoperatively. MAIN OUTCOME MEASURE The primary endpoint was considered moderate to severe CRBD immediately postoperatively. Secondary endpoints included moderate to severe CRBD at 1, 2 and 6 h postoperatively. Additionally, postoperative pain, patient satisfaction, and TENS-related adverse effects were evaluated. RESULTS Moderate to severe CRBD immediately postoperatively was significantly less frequent in the TENS group than in the control group: 10 (17.9%) vs. 34 (60.7%); P < 0.001; relative risk (95% CI) = 0.294 (0.161 to 0.536); absolute risk reduction = 0.43; number needed to treat = 2.3. Moderate to severe CRBD differed between the two groups at 1 h postoperatively: 1 (1.8%) vs. 16 (28.6%); P < 0.001; relative risk = 0.06 (95% CI 0.01 to 0.46); absolute risk reduction = 0.27; number needed to treat = 3.7. The TENS group exhibited a significantly lower score for postoperative pain at 1 h (1.8 ± 0.6 vs. 2.2 ± 0.4; P < 0.001, mean difference (95% CI) = 0.4 (0.2 to 0.6) and a higher score for patient satisfaction, 5.0 (4.0 to 6.0) vs. 3.0 (3.0 to 4.0); P < 0.001; median difference (95% CI) = 2.0 (1.0 to 2.0). CONCLUSIONS TENS reduced moderate to severe CRBD, decreased postoperative pain, and increased patient satisfaction after TURBT. CLINICAL TRIAL REGISTRY Clinical Research Information Service (KCT0007450)
Pain after laparoscopic cholecystectomy (LC) is multifactorial and usually not effectively treated. Rectus sheath block (RSB) has been proven to reduce the pain from midline abdominal incision and laparoscopic surgery. We investigated the preemptive analgesic effect of RSB after LC.In this prospective, randomized, single-center trial, 200 patients undergoing LC were randomized into preoperative RSB (pre-RSB) or postoperative RSB (post-RSB) group. An ultrasound-guided RSB was performed before skin incision in the pre-RSB group or after skin closure in the post-RSB group. The primary outcome was total rescue analgesic consumption at 24 h post-surgery. The secondary outcomes were cumulated rescue analgesic consumption and postoperative pain measured by numerical rating scale (NRS) at 0, 1, 2, 6, 9, 18, and 24 h post-surgery.Total rescue analgesic consumption at 24 h post-surgery was significantly lower in the pre-RSB group than in the post-RSB group (p = 0.020). The cumulated rescue analgesic consumption was significantly lower in the pre-RSB group than in the post-RSB group at 1 h (p = 0.023), 9 h (p = 0.020) and 18 h (p = 0.002) post-surgery. NRS was significantly lower in the pre-RSB group than in the post-RSB group at 0 h post-surgery (p = 0.023).The pre-RSB reduced the analgesic requirements in patients undergoing LC compared with the post-RSB.
Background: The ganglion impar (ganglion of Walther) block has been used to manage coccygeal and perineal (perianal and genital) pain due to both benign and malignant causes. However, the factors associated with successful responses to ganglion impar block are unknown. Therefore, in the present study, we aimed to identify the independent factors associated with successful responses to ganglion impar block in patients with chronic pain in coccygeal and perineal regions. Methods: From January 2008 to December 2017, we performed a retrospective review of 106 patients who underwent ganglion impar block. Patients were considered successful responders if they reported a decrease of more than 50% or 4 points on the 11-point (0 = no pain and 10 = worst possible pain) numerical rating scale 1 month after the procedure, while others were considered non-responders. Logistic regression analysis was performed to identify factors independently associated with successful responses at 1 month after the procedure. Results: Multivariable logistic regression analysis showed that cancer-related causes were significantly associated with successful responses at 1 month after ganglion impar block (odds ratio = 2.60, 95% confidence interval = 1.05 to 6.43, P = 0.038). Conclusion: Ganglion impar block may be more effective in cancer-related pain than pain due to benign causes.
Knee osteoarthritis (OA) is a prevalent and debilitating musculoskeletal condition that significantly affects the quality of life of millions of individuals worldwide. In recent years, cooled radiofrequency ablation (CRFA) has become a viable treatment option for knee OA. This review thoroughly evaluated the existing literature on CRFA therapy for knee OA. It delved into the mechanisms behind CRFA, evaluated its clinical efficacy, and investigated potential avenues for future research and application. The insights gained from this review are crucial for healthcare professionals, researchers, and policymakers, offering an updated perspective on CRFA's role as a viable therapeutic option for knee OA.
Several treatment modalities have been proposed for foraminal stenosis, but the treatment options remain unsatisfactory. Previous studies have shown that transforaminal balloon adhesiolysis may be effective in patients with refractory lumbar foraminal stenosis. However, in patients with a high iliac crest, balloon catheter insertion may be difficult via a conventional transforaminal approach (particularly targeting the L5-S1 foramen). It has been reported that an epidural catheter can be placed easily by a contralateral interlaminar retrograde foraminal approach. Therefore, we applied this approach to L5-S1 transforaminal balloon adhesiolysis in patients with a high iliac crest. We retrospectively analyzed data from 22 patients who underwent combined epidural adhesiolysis and balloon decompression (balloon adhesiolysis) using the novel foraminal balloon catheter via a contralateral interlaminar retrograde foraminal approach. The pain intensity significantly decreased over the three-month period after balloon adhesiolysis (p < 0.001). There were no complications associated with the balloon procedure. The present study suggests that balloon adhesiolysis for L5-S1 foramen via a contralateral interlaminar retrograde foraminal approach may be an effective alternative for patients with a high iliac crest and refractory lumbar radicular pain due to lumbar foraminal stenosis. In addition, detailed procedural aspects are described here.
Background: A high fresh gas flow of >5 L/minute is commonly used for emergence from inhalation anesthesia. In addition, a high fresh gas flow may have detrimental effects on climate change. However, no study has determined the optimal fresh gas flow for emergence from inhalation anesthesia. Therefore, we compared the effect of fresh gas flows of 5 L/minute and 10 L/minute on emergence time from sevoflurane anesthesia. Methods: Patients who were scheduled for transurethral resection of bladder tumor were randomly assigned to receive fresh gas flows of 5 L/minute (group 5) or 10 L/minute (group 10) during emergence. Emergence time was defined as the time from discontinuation of sevoflurane to tracheal extubation. The primary outcome was the emergence time, and the secondary outcomes were the time to self-movement and the time to eye-opening. Results: A total of 54 patients were included. In groups 5 and 10, emergence time (12.1 ± 2.9 minutes vs 11.1 ± 2.7 minutes, respectively; P = .232), time to self-movement (9.4 ± 3.8 minutes vs 8.5 ± 4.6 minutes, respectively; P = .435), and time to eye-opening (11.5 ± 3.1 minute vs 10.6 ± 3.0 minutes, respectively; P = .252) were not significantly different. Conclusions: Emergence time, time to self-movement, and time to eye opening were not significantly different between fresh gas flow rates of 5 L/minute and 10 L/minute in transurethral resection of bladder tumor, thus suggesting that fresh gas flow of 5 L/minute is sufficient for emergence from sevoflurane anesthesia. Trial registration: ClinicalTrials.gov (NCT05376631).
Abstract Individuals with myotonic dystrophy type 1 (DM1) reportedly have a higher risk of postoperative complications than those without DM1; however, factors related to perioperative complications in DM1 patients remain unclear. We aimed to identify the risk factors that may be associated with postoperative complications in DM1 patients. We reviewed medical records of 256 patients with DM1 from 1998 to 2018, among whom 42 (16.4%) had previously undergone 51 surgeries under general and regional anaesthesia. Among the 42 patients, 11 (21.5%) had 13 postoperative complications including respiratory complications, sustained hypotension, wound infection and dehiscence, artery thrombosis and occlusion, and delayed recovery from anaesthesia. There were significant inter-group differences between the non-complicated and complicated groups considering the following parameters: high-grade (≥ 3) muscular impairment rating scale (MIRS), extubation time, postoperative opioid use, and hospital length of stay. Furthermore, univariate analysis revealed that an MIRS score ≥ 3 (odds ratio [OR] 9.346, confidence interval [CI] 1.761–49.595, p = 0.009) and postoperative opioid use (OR 8.000, CI 1.772–36.127, p = 0.007) were the only statistically significant factors. Therefore, clinicians should be cautious in administering opioids, particularly in patients with a high-grade MIRS score during the perioperative period.
In this paper, we propose a novel selective coding scheme based on layered structure. The scheme has 4 functional blocks that are target extraction, first layer coder for background region (FLC), second layer coder for target region (SLC) and buffer controller. For the target extraction process, we use motion vector grouping and change detection techniques, and increase the extraction accuracy of the target region by using a global motion compensation. The FLC and SLC are coders based on H.261 structure and generate low resolution background and high resolution target image, respectively. Simulation results show that the average PSNRs are obtained about 45.05 dB and 26.02 dB for target and background region respectively. Also the average number of bits generated in a frame is about 4780 bits: 2.16 bits and 41.84 bits per block are assigned to background and target region, respectively.