Recently, deep learning-based methods have been established to denoise the low-count positron emission tomography (PET) images and predict their standard-count image counterparts, which could achieve reduction of injected dosage and scan time, and improve image quality for equivalent lesion detectability and clinical diagnosis. In clinical settings, the majority scans are still acquired using standard injection dose with standard scan time. In this work, we applied a 3D U-Net network to reduce the noise of standard-count PET images to obtain the virtual-high-count (VHC) PET images for identifying the potential benefits of the obtained VHC PET images.The training datasets, including down-sampled standard-count PET images as the network input and high-count images as the desired network output, were derived from 27 whole-body PET datasets, which were acquired using 90-min dynamic scan. The down-sampled standard-count PET images were rebinned with matched noise level of 195 clinical static PET datasets, by matching the normalized standard derivation (NSTD) inside 3D liver region of interests (ROIs). Cross-validation was performed on 27 PET datasets. Normalized mean square error (NMSE), peak signal to noise ratio (PSNR), structural similarity index (SSIM), and standard uptake value (SUV) bias of lesions were used for evaluation on standard-count and VHC PET images, with real-high-count PET image of 90 min as the gold standard. In addition, the network trained with 27 dynamic PET datasets was applied to 195 clinical static datasets to obtain VHC PET images. The NSTD and mean/max SUV of hypermetabolic lesions in standard-count and VHC PET images were evaluated. Three experienced nuclear medicine physicians evaluated the overall image quality of randomly selected 50 out of 195 patients' standard-count and VHC images and conducted 5-score ranking. A Wilcoxon signed-rank test was used to compare differences in the grading of standard-count and VHC images.The cross-validation results showed that VHC PET images had improved quantitative metrics scores than the standard-count PET images. The mean/max SUVs of 35 lesions in the standard-count and true-high-count PET images did not show significantly statistical difference. Similarly, the mean/max SUVs of VHC and true-high-count PET images did not show significantly statistical difference. For the 195 clinical data, the VHC PET images had a significantly lower NSTD than the standard-count images. The mean/max SUVs of 215 hypermetabolic lesions in the VHC and standard-count images showed no statistically significant difference. In the image quality evaluation by three experienced nuclear medicine physicians, standard-count images and VHC images received scores with mean and standard deviation of 3.34±0.80 and 4.26 ± 0.72 from Physician 1, 3.02 ± 0.87 and 3.96 ± 0.73 from Physician 2, and 3.74 ± 1.10 and 4.58 ± 0.57 from Physician 3, respectively. The VHC images were consistently ranked higher than the standard-count images. The Wilcoxon signed-rank test also indicated that the image quality evaluation between standard-count and VHC images had significant difference.A DL method was proposed to convert the standard-count images to the VHC images. The VHC images had reduced noise level. No significant difference in mean/max SUV to the standard-count images was observed. VHC images improved image quality for better lesion detectability and clinical diagnosis.
We previously proposed a fast maximum a posteriori (MAP) algorithm, limited-memory Broyden-Fletcher-Goldfarb-Shanno with boundary constrains (LBFGS-B-PC), combining LBFGS-B with diagonal preconditioning. Previous results have shown in simulations that it converges using around 40 projections independent of many factors. The aim of this study is to improve the algorithm further by using a better initial image and a modified preconditioner that is less sensitive to noise and data scale. By initializing the algorithm with the best initial image (one full iteration of OSEM with 35 subsets), ROI values can converge almost twice as fast for the same computation time. Moreover, the new preconditioner makes the performance more consistent between high and low count data sets. In addition, we have found a means to choose the stopping criteria to reach a desired level of quantitative accuracy in the reconstructed image. Based on the results with patient data, the optimized LBFGS-B-PC shows promise for clinical imaging.
This study explores the feasibility of incorporating energy information into a maximum-likelihood reconstruction of activity and attenuation (MLAA) framework. The attenuation and activity distributions were reconstructed from multiple energy window data, and a scatter function was added to the system model of the algorithm. The proposed energy-based method (MLAA-EB) was evaluated with simulated 3D phantom data, using the geometry and characteristics of a Siemens mMR PET-MR scanner. Results showed that the proposed algorithm is able to compensate for errors in the activity image caused by the incorrect assignment of attenuation values to the segmented MR. This is effective for small objects only, for large objects further solutions need to be found.
Positron emission tomography (PET) imaging with various tracers is increasingly used in Alzheimer's disease (AD) studies. However, access to PET scans using new or less-available tracers with sophisticated synthesis and short half-life isotopes may be very limited. Therefore, it is of great significance and interest in AD research to assess the feasibility of generating synthetic PET images of less-available tracers from the PET image of another common tracer, in particular
Two algorithms for solving misalignment issues in penalized PET/CT reconstruction using anatomical priors are proposed. Both approaches are based on a recently published joint motion estimation and image reconstruction method. The first approach deforms the anatomical image to align it with the functional one while the second approach deforms both images to align them with the measured data. Our current implementation alternates between image reconstruction and alignment estimation. To evaluate the potential of these approaches, we have chosen Parallel Level Sets (PLS) as a representative anatomical penalty, incorporating a spatially-variant penalty strength to achieve uniform local contrast. The performance was evaluated using simulated non-TOF data generated with an XCAT phantom in the thorax region. We used the attenuation image in the anatomical prior. The results demonstrated that both methods can estimate the misalignment and deform the anatomical image accordingly. However, the performance of the first approach depends highly on the workflow of the alternating process. The second approach shows a faster convergence rate to the correct alignment and is less sensitive to the workflow. Interestingly, the presence of anatomical information can improve the convergence rate of misalignment estimation for the second approach but slow it down for the first approach.