Thoracic endovascular aortic repair (TEVAR) of aortic aneurysms and dissections involving the arch has evolved over the last two decades. Compared to conventional surgical methods, endovascular repair offers a less invasive treatment option with lower risk and faster recovery. Endografts used in TEVAR vary in design depending on the procedure and application. Novel endografts (e.g., branched stent-graft) were developed to ensure perfusion of blood to the supra-aortic vessels, but their haemodynamic performance and long-term durability have not been adequately studied. This review focuses on the use of computational modelling to study haemodynamics in commercially available endografts designed for complex aortic arch repair. First, we summarise the currently adopted workflow for computational fluid dynamics (CFD) modelling, including geometry reconstruction, boundary conditions, flow models, and haemodynamic metrics of interest. This is followed by a review of recently (2010-present) published CFD studies on complex aortic arch repair, using both idealized and patient-specific models. Finally, we introduce some of the promising techniques that can be potentially applied to predict post-operative outcomes.
This study aims to investigate the haemodynamic response induced by implantation of a double-branched endograft used in thoracic endovascular aortic repair (TEVAR) of the aortic arch. Anatomically realistic models were reconstructed from CT images obtained from patients who underwent TEVAR using the RelayPlus double-branched endograft implanted in the aortic arch. Two cases (Patient 1, Patient 2) were included here, both patients presented with type A aortic dissection before TEVAR. To examine the influence of inner tunnel branch diameters on localised flow patterns, three tunnel branch diameters were tested using the geometric model reconstructed for Patient 1. Pulsatile blood flow through the models was simulated by numerically solving the Navier-Stokes equations along with a transitional flow model. The physiological boundary conditions were imposed at the model inlet and outlets, while the wall was assumed to be rigid. Our simulation results showed that the double-branched endograft allowed for the sufficient perfusion of blood to the supra-aortic branches and restored flow patterns expected in normal aortas. The diameter of tunnel branches in the device plays a crucial role in the development of flow downstream of the branches and thus must be selected carefully based on the overall geometry of the vessel. Given the importance of wall shear stress in vascular remodelling and thrombus formation, longitudinal studies should be performed in the future in order to elucidate the role of tunnel branch diameters in long-term patency of the supra-aortic branches following TEVAR with the double-branched endograft.
Experiential learning is an integral component of engineering education. The Chemeng Remote Experience Augmented through TEchnology (CREATE) labs concept was implemented in the academic year 2020–21 in response to COVID19 for first-, second-, and third-year chemical engineering undergraduate students studying at Imperial College London. Using a range of technologies including pan-tilt-zoom cameras and Microsoft HoloLens 2 to provide real-time views of the lab environment from anywhere in the world. Students could control the experiments remotely while graduate teaching assistants (GTAs) operated the equipment based on the students' instructions. This study is aimed at assessing the effectiveness of this implementation with a focus on student communication and confidence. Students and GTAs were surveyed at the end of labs, and a year-dependent response was observed. The majority of students (>70%) reported experiencing effective communication with team members and GTAs and there was a strong positive correlation between communication and confidence in applying engineering concepts in the labs (χ2 = 79.96; p = 1.69 ×10−10). 5–10% of students from all year groups reported that they disliked the lack of in-person activities. The majority (>90%) of GTAs assisting with experiments stated that they associated their role in the CREATE labs with that of a facilitator. The overall delivery of CREATE labs during academic year 2020–21 was positively received by both students and GTAs with recommendations for in-person activities for first- and second-year students. With minor modifications, CREATE labs has the potential to prepare students for effective remote communication and gain experience in using smart technologies which are key components of Industry 4.0.
Thoracic endovascular aortic repair (TEVAR) of the arch is challenging given its complex geometry and the involvement of supra-aortic arteries. Different branched endografts have been designed for use in this region, but their haemodynamic performance and the risk for post-intervention complications are not yet clear. This study aims to examine aortic haemodynamics and biomechanical conditions following TVAR treatment of an aortic arch aneurysm with a two-component single-branched endograft.Computational fluid dynamics and finite element analysis were applied to a patient-specific case at different stages: pre-intervention, post-intervention and follow-up. Physiologically accurate boundary conditions were used based on available clinical information.Computational results obtained from the post-intervention model confirmed technical success of the procedure in restoring normal flow to the arch. Simulations of the follow-up model, where boundary conditions were modified to reflect change in supra-aortic vessel perfusion observed on the follow-up scan, predicted normal flow patterns but high levels of wall stress (up to 1.3M MPa) and increased displacement forces in regions at risk of compromising device stability. This might have contributed to the suspected endoleaks or device migration identified at the final follow up.Our study demonstrated that detailed haemodynamic and biomechanical analysis can help identify possible causes for post-TEVAR complications in a patient-specific setting. Further refinement and validation of the computational workflow will allow personalised assessment to aid in surgical planning and clinical decision making.