BackgroundCurrently, 2-dimensional ultrasound estimation of fetal size rather than fetal growth is used to define fetal growth restriction, but single estimates in late pregnancy lack sensitivity and may identify small for gestational age rather than growth restriction. Single or longitudinal measures of 3-dimensional fractional thigh volume may address this problem.ObjectiveWe sought to derive normal values for 3-dimensional fractional thigh volume in the third trimester, determine if fractional thigh volume is superior to 2-dimensional ultrasound biometry alone for detecting fetal growth restriction, and determine whether individualized growth assessment parameters have the potential to identify fetal growth restriction remote from term delivery.Study DesignThis was a longitudinal prospective cohort study of 115 unselected pregnancies in a tertiary referral unit (St Mary’s Hospital, Manchester, United Kingdom). Standard 2-dimensional ultrasound biometry measurements were obtained, along with fractional thigh volume measurements (based on 50% of the femoral diaphysis length). Measurements were used to calculate estimated fetal weight (Hadlock). Individualized growth assessment parameters and percentage deviations in longitudinally measured biometrics were determined using a Web-based system (iGAP; http://iGAP.research.bcm.edu). Small for gestational age was defined <10th and fetal growth restriction <3rd customized birthweight centile. Logistic regression was used to compare estimated fetal weight (Hadlock), estimated fetal weight (biparietal diameter–abdominal circumference–fractional thigh volume), fractional thigh volume, and abdominal circumference for the prediction of small for gestational age or fetal growth restriction at birth. Screening performance was assessed using area under the receiver operating characteristic curve.ResultsThere was a better correlation between fractional thigh volume and estimated fetal weight ((biparietal diameter–abdominal circumference–fractional thigh volume) obtained at 34-36 weeks with birthweight than between 2-dimensional biometry measures such as abdominal circumference and estimated fetal weight (Hadlock). There was also a modest improvement in the detection of both small for gestational age and fetal growth restriction using fractional thigh volume–derived measures compared to standard 2-dimensional measurements (area under receiver operating characteristic curve, 0.86; 95% confidence interval, 0.79–0.94, and area under receiver operating characteristic curve, 0.92; 95% confidence interval, 0.85–0.99, respectively).ConclusionFractional thigh volume measurements offer some improvement over 2-dimensional biometry for the detection of late-onset fetal growth restriction at 34-36 weeks. Currently, 2-dimensional ultrasound estimation of fetal size rather than fetal growth is used to define fetal growth restriction, but single estimates in late pregnancy lack sensitivity and may identify small for gestational age rather than growth restriction. Single or longitudinal measures of 3-dimensional fractional thigh volume may address this problem. We sought to derive normal values for 3-dimensional fractional thigh volume in the third trimester, determine if fractional thigh volume is superior to 2-dimensional ultrasound biometry alone for detecting fetal growth restriction, and determine whether individualized growth assessment parameters have the potential to identify fetal growth restriction remote from term delivery. This was a longitudinal prospective cohort study of 115 unselected pregnancies in a tertiary referral unit (St Mary’s Hospital, Manchester, United Kingdom). Standard 2-dimensional ultrasound biometry measurements were obtained, along with fractional thigh volume measurements (based on 50% of the femoral diaphysis length). Measurements were used to calculate estimated fetal weight (Hadlock). Individualized growth assessment parameters and percentage deviations in longitudinally measured biometrics were determined using a Web-based system (iGAP; http://iGAP.research.bcm.edu). Small for gestational age was defined <10th and fetal growth restriction <3rd customized birthweight centile. Logistic regression was used to compare estimated fetal weight (Hadlock), estimated fetal weight (biparietal diameter–abdominal circumference–fractional thigh volume), fractional thigh volume, and abdominal circumference for the prediction of small for gestational age or fetal growth restriction at birth. Screening performance was assessed using area under the receiver operating characteristic curve. There was a better correlation between fractional thigh volume and estimated fetal weight ((biparietal diameter–abdominal circumference–fractional thigh volume) obtained at 34-36 weeks with birthweight than between 2-dimensional biometry measures such as abdominal circumference and estimated fetal weight (Hadlock). There was also a modest improvement in the detection of both small for gestational age and fetal growth restriction using fractional thigh volume–derived measures compared to standard 2-dimensional measurements (area under receiver operating characteristic curve, 0.86; 95% confidence interval, 0.79–0.94, and area under receiver operating characteristic curve, 0.92; 95% confidence interval, 0.85–0.99, respectively). Fractional thigh volume measurements offer some improvement over 2-dimensional biometry for the detection of late-onset fetal growth restriction at 34-36 weeks.
Background Pre-eclampsia is a leading cause of maternal and perinatal mortality and morbidity. Early identification of women at risk is needed to plan management. Objectives To assess the performance of existing pre-eclampsia prediction models and to develop and validate models for pre-eclampsia using individual participant data meta-analysis. We also estimated the prognostic value of individual markers. Design This was an individual participant data meta-analysis of cohort studies. Setting Source data from secondary and tertiary care. Predictors We identified predictors from systematic reviews, and prioritised for importance in an international survey. Primary outcomes Early-onset (delivery at < 34 weeks’ gestation), late-onset (delivery at ≥ 34 weeks’ gestation) and any-onset pre-eclampsia. Analysis We externally validated existing prediction models in UK cohorts and reported their performance in terms of discrimination and calibration. We developed and validated 12 new models based on clinical characteristics, clinical characteristics and biochemical markers, and clinical characteristics and ultrasound markers in the first and second trimesters. We summarised the data set-specific performance of each model using a random-effects meta-analysis. Discrimination was considered promising for C -statistics of ≥ 0.7, and calibration was considered good if the slope was near 1 and calibration-in-the-large was near 0. Heterogeneity was quantified using I 2 and τ 2 . A decision curve analysis was undertaken to determine the clinical utility (net benefit) of the models. We reported the unadjusted prognostic value of individual predictors for pre-eclampsia as odds ratios with 95% confidence and prediction intervals. Results The International Prediction of Pregnancy Complications network comprised 78 studies (3,570,993 singleton pregnancies) identified from systematic reviews of tests to predict pre-eclampsia. Twenty-four of the 131 published prediction models could be validated in 11 UK cohorts. Summary C -statistics were between 0.6 and 0.7 for most models, and calibration was generally poor owing to large between-study heterogeneity, suggesting model overfitting. The clinical utility of the models varied between showing net harm to showing minimal or no net benefit. The average discrimination for IPPIC models ranged between 0.68 and 0.83. This was highest for the second-trimester clinical characteristics and biochemical markers model to predict early-onset pre-eclampsia, and lowest for the first-trimester clinical characteristics models to predict any pre-eclampsia. Calibration performance was heterogeneous across studies. Net benefit was observed for International Prediction of Pregnancy Complications first and second-trimester clinical characteristics and clinical characteristics and biochemical markers models predicting any pre-eclampsia, when validated in singleton nulliparous women managed in the UK NHS. History of hypertension, parity, smoking, mode of conception, placental growth factor and uterine artery pulsatility index had the strongest unadjusted associations with pre-eclampsia. Limitations Variations in study population characteristics, type of predictors reported, too few events in some validation cohorts and the type of measurements contributed to heterogeneity in performance of the International Prediction of Pregnancy Complications models. Some published models were not validated because model predictors were unavailable in the individual participant data. Conclusion For models that could be validated, predictive performance was generally poor across data sets. Although the International Prediction of Pregnancy Complications models show good predictive performance on average, and in the singleton nulliparous population, heterogeneity in calibration performance is likely across settings. Future work Recalibration of model parameters within populations may improve calibration performance. Additional strong predictors need to be identified to improve model performance and consistency. Validation, including examination of calibration heterogeneity, is required for the models we could not validate. Study registration This study is registered as PROSPERO CRD42015029349. Funding This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment ; Vol. 24, No. 72. See the NIHR Journals Library website for further project information.
A multidisciplinary team operating in a secondary- or tertiary-care setting is a commonly adopted model for the provision of pregnancy care to women with diabetes. This chapter suggests important characteristics of a multidisciplinary team. It also presents simple practical advice on how to provide a diabetes-in-pregnancy service meeting the standards recommended in the UK National Institute for Health and Care Excellence (NICE) guidelines. The overall aims of multidisciplinary joint antenatal diabetes care are to allow the mother to have a good experience of pregnancy, excellent glycemic control, and a normal delivery of a healthy baby. In order to maintain and improve the standard of pregnancy care, there is the need for regular, simple standard audits conducted at local, regional, and national levels. The ability of individual hospitals and care providers to be able to benchmark against regional/national performance is very useful in driving improvements in care, particularly as a method of securing additional resources.
To assess intraexaminer and interexaminer reliability of 3-dimensional fetal sonographic measurements.Three-dimensional fetal organ volumes (head, kidney, total thigh volume, and fractional thigh volume) were acquired during the second and third trimesters, with the addition of placental volume in the second trimester, by 2 different experienced, blinded sonographers. Fifty-eight fetuses were examined from 21 to 39 weeks' gestation. Intraexaminer and Interexaminer reliability was assessed with Bland-Altman plots, and their 95% limits of agreement and intraclass correlation coefficients.The most significant interexaminer error was observed in the second-trimester kidney volume (95% limits of agreement, ± 110%), and the best agreement was for the third-trimester fractional thigh volume (95% limits of agreement, ± 25%) and second-trimester head volume (95% limits of agreement, -7%-25%). Second- and third-trimester intraclass correlation coefficient results were all greater than 0.75, apart from second-trimester kidney volume intraexaminer (0.374) and interexaminer (0.061) measurements, second-trimester placenta interexaminer measurements (0.390), and third-trimester kidney interexaminer measurements (0.647).Three-dimensional fetal sonographic volumes of the head, kidney, total thigh, and placenta have limited reproducibility, and improvements in measurement techniques are needed before they can be used routinely to assess fetal growth. The 3-dimensional fractional thigh volume can be reliably obtained in the late third trimester.
Objective: To investigate the effect of TNF-α on the endothelial function of human systemic arteries. Methods: Omental arteries were obtained from healthy pregnant women undergoing Cesarean section and examined using isometric wire myography. Results: Incubation with TNF-α (1nM) alone did not alter bradykinin-mediated endothelium-dependent relaxation of arteries. However, TNF-α did attenuate nitric oxide- (NO) and prostacyclin-independent endothelial-mediated relaxation. Similarly, in vessels constricted with a high potassium solution (60 mM), which inhibits vasodilatation via endothelial-derived hyperpolarising factor (EDHF), TNF-α incubation also attenuated bradykinin-induced vasodilatation. Conclusions: The vasorelaxant capacity of human systemic arteries is compromised by TNF-α incubation in the presence of NO/prostacyclin or EDHF-blockade.