As part of the process of developing a decision aid for carpal tunnel syndrome (CTS) according to the Ottawa Decision Support Framework, we were interested in the level of 'decisional conflict' of hand surgeons and patients with CTS. This study addresses the null hypothesis that there is no difference between surgeon and patient decisional conflict with respect to test and treatment options for CTS. Secondary analyses assess the impact of patient and physician demographics and the strength of the patient-physician relationship on decisional conflict.One-hundred-twenty-three observers of the Science of Variation Group (SOVG) and 84 patients with carpal tunnel syndrome completed a survey regarding the Decisional Conflict Scale. Patients also filled out the Pain Self-efficacy Questionnaire (PSEQ) and the Patient Doctor Relationship Questionnaire (PDRQ-9).On average, patients had significantly greater decision conflict and scored higher on most subscales of the decisional conflict scale than hand surgeons. Factors associated with greater decision conflict were specific hand surgeon, less self-efficacy (confidence that one can achieve one's goals in spite of pain), and higher PDRQ (relationship between patient and doctor). Surgeons from Europe have--on average--significantly more decision conflict than surgeons in the United States of America.Patients with CTS have more decision conflict than hand surgeons. Decision aids might help narrow this gap in decisional conflict.
External fixation of fractures of the distal end of the radius neutralizes external forces and maintains axial alignment during healing. As far as we know, there have been no biomechanical studies of the effects of early removal of the fixator in a partially healed fracture model. The purpose of the present study was to observe the load-displacement behavior of a distal radial fracture model in which we had simulated partial healing by injection of butyl-rubber caulk and augmented this simulated healing with Kirschner-wire fixation. Sixteen fresh-frozen hand-wrist-forearm specimens from cadavera were mounted in mid-rotation in resin pots, and a load was applied. An osteotomy was used to simulate the fracture. Relative motion at the site of the osteotomy was compared, with use of a three-dimensional Optotrak kinematic device, during physiological loading of six constructs with Kirschner-wire transfixion or outrigger fixation. In the experimental group, partial healing was simulated by injection of butyl-rubber caulk into the site of the osteotomy and testing with simulated muscle-loading was performed through a full range of motion of the wrist. No difference could be detected between the relative motion at the osteotomy sites that had been treated with standard fully augmented external fixation and that in the experimental group (p > 0.05). T test analysis revealed that motion was equivalent regardless of whether Kirschner-wire transfixion or outrigger fixation had been used (p = 0.62) and that all of the augmented constructs had significantly less relative motion than all of the nonaugmented constructs (p < 0.001).CLINICAL RELEVANCE: In clinical practice, early removal of a standard external fixator is desirable to prevent stiffness, provided that the removal does not decrease the stability of the fracture. We found that the combination of partial simulated healing and augmentation with Krischner wires in vitro provided stability that was comparable with that provided by full fixation without simulated healing in an acute-fracture model. These findings support the concept of modular disassembly of the external fixator to allow an early range of motion of the wrist.