A non-contact arterial-induced skin vibration inspection system is implemented. This optical metrology system is constructed with shadow Moiré configuration and the fringe analysis algorithm. Developed with the Region of Interested (ROI) capturing technique and the Two-dimensional Wavelet Transform (2D-CWT) method, this algorithm is able to retrieve the height-correlated phase information from the shadow Moiré fringe patterns. Using a commercial video camera or a CMOS image sensor, this system could monitor the skin-vibration induced by the cyclic deformation of inner layered artery. The cross-sectional variation and the rhythm of heart cycle could be continuously measured for health monitoring purposes. The average vibration amplitude of the artery at the wrist ranges between 20 μm and 50 μm, which is quite subtle comparing with the skin surface structure. Having the non-stationary motion of human body, the traditional phase shifting (PS) technique can be very unstable due to the requirement of several frames of images, especially for case that artery is continuously pumping. To bypass this fundamental issue, the shadow Moiré technique is introduced to enhance the surface deformation characteristic. And the phase information is retrieved by the means of spectrum filtering instead of PS technique, which the phase is calculated from intensity maps of multiple images. The instantaneous surface can therefore be reconstructed individually from each frame, enabling the subtle arterial-induced skin vibration measurement. The comparative results of phase reconstruction between different fringe analysis algorithms will be demonstrated numerically and experimentally. And the electrocardiography (ECG) results will used as the reference for the validity of health monitoring potential of the non-contact arterial-induced skin vibration inspection system.
Nowadays, the classical modeling of quartz crystal microbalance (QCM) describes the relationship between frequency and mass; resistance and viscosity are widely accepted and used for many years. It is clear that the mass loading decreases the resonance frequency, and the viscoelastic damping increases the resistance of quartz resoance. Due to rapidly advancement of electronics techniques, these effects can be easily read out through an advanced electronic circuitry precisely. However, the influence of the oscillatory condition by a bio-molecule layer on the top of quartz is more complex and beyond the scope of classical model due to coupled vicoelastic effect. The dynamics of the quartz crystal shear mode resonance are difficult observed by traditional metrology techniques because of the very small vibration amplitude. Scanning tunneling microscope (STM) which can scan the surface in atomic level provides a new route to study and analyze the interaction between quartz and bio-molecule viscoelastic layers. STM not only can detect the tiny vibrational changes but also can observes the process of growth of a viscoelastic layer consisting of biological materials. The measurement of dynamic behaviors of QCM with STM will be presented in this paper.
We developed a modified photonic Doppler velocimetry (PDV) configuration which possesses the ability to record wide-range velocity information to evaluate composite material fracture behavior. With the laminate and tunnel design of a fragment generator, the controllable parameters such as fragment size and applied voltage can provide the flexibility for dynamic evaluation under different momentum conditions. We obtained velocity profiles using continuous wavelet transforms and by using our proposed velocity line tracing algorithm. Simulated heterodyne signals and surface morphology of fractures were examined to verify the heterodyne signals. We observed that the obtained tunnel-end velocity of the fragment generator was proportional to the applied voltage.
Abstract We investigated the design parameters of a compact pot-like ultrasonic sensor which possesses a highly anisotropic beam pattern. As the sensor size is small due to its application constraint, the parameters are thus highly coupled to one another. We analyzed the respective effects of the parameters in the case where there is a vertical beam width reduction. The parameters investigated include resonant frequency, vibrating plate width-expanded angle, and ratio of thickness discontinuity of the vibrating plate. Numerical models developed by combining finite-element analysis and spatial Fourier transforms were adopted to predict the far-field radiating beam pattern of the various design configurations. The displacement distribution of the vibrating plate was measured using a microscopic laser Doppler vibrometer and the far-field pressure beam patterns were measured using a standard microphone in a semianechoic environment. The three configurations we used to validate the simulation model resulted in an H-V ratio of 2.67, 2.68 and 3.13, respectively which all agreed well with the numerical calculations. We found that by increasing the operating resonant frequency from 40kHz to 58kHz, the vertical far-field beam width of an ultrasonic sensor can be reduced by 31.62%. We found that the vertical beam width can be significantly reduced when the ratio of the thickness discontinuity of the vibrating plate decreases from 1 to 0.4 and is incorporated with its optimal width-expanded angle of the vibrating plate. It appears that an ultrasonic sensor with this type of anisotropic beam pattern can be ideally adopted for today's automotive applications.
A pressure ulcer is one of the most important concerns for wheelchair bound patients with spinal cord injuries. A pressure ulcer is a localized injury near the buttocks that bear ischial tuberosity oppression over a long period of time. Due to elevated compression to blood vessels, the surrounding tissues suffer from a lack of oxygen and nutrition. The ulcers eventually lead to skin damage followed by tissue necrosis. The current medical strategy is to minimize the occurrence of pressure ulcers by regularly helping patients change their posture. However, these methods do not always work effectively or well. As a solution to fundamentally prevent pressure ulcers, a smart air cushion system was developed to detect and control pressure actively. The air cushion works by automatically adjusting a patient's sitting posture to effectively relieve the buttock pressure. To analyze the correlation between the dynamic pressure profiles of an air cell with a patient's weight, a projection Moiré system was adopted to measure the deformation of an air cell and its associated stress distribution. Combining a full-field deformation imaging with air pressure measured within an air cell, the patient's weight and the stress distribution can be simultaneously obtained. By integrating a full-field optical metrology with a time varying pressure sensor output coupled with different active air control algorithms for various designs, we can tailor the ratio of the air cells. Our preliminary data suggests that this newly developed smart air cushion has the potential to selectively reduce localized compression on the tissues at the buttocks. Furthermore, it can take a patient's weight which is an additional benefit so that medical personnel can reference it to prescribe the correct drug dosages.