Coronavirus disease 2019 (COVID-19) leads to thoracic complications requiring surgery. This is challenging, particularly in patients supported with venovenous extracorporeal membrane oxygenation (VV-ECMO) due to the need for continuous therapeutic anticoagulation. We aim to share our experience regarding the safety and perioperative management of video-assisted thoracic surgery for this specific population.Retrospective, single-center study between November 2020 and January 2022 at the ICU department of a 1.061-bed tertiary care and VV-ECMO referral center during the COVID-19 pandemic.48 COVID-19 patients were supported with VV-ECMO. A total of 14 video-assisted thoracic surgery (VATS) procedures were performed in seven patients. Indications were mostly hemothorax (85.7%). In eight procedures heparin was stopped at least 1 h before incision. A total of 10 circuit changes due to clot formation or oxygen transfer failure were required in six patients (85.7%). One circuit replacement seemed related to the preceding VATS procedure, although polytransfusion might be a contributing factor. None of the mechanical complications was fatal. Four VATS-patients (57.1%) died, of which two (50%) immediately perioperatively due to uncontrollable bleeding. All three survivors were treated with additional transarterial embolization.(1) Thoracic complications in COVID-19 patients on VV-ECMO are common. (2) Indication for VATS is mostly hemothorax (3) Perioperative mortality is high, mostly due to uncontrollable bleeding. (4) Preoperative withdrawal of anticoagulation is not directly related to a higher rate of ECMO circuit-related complications, but a prolonged duration of VV-ECMO support and polytransfusion might be. (5) Additional transarterial embolization to control postoperative bleeding may further improve outcomes.
To describe a simple, noninvasive technique to detect changes in oxygen saturation at the level of the spinal cord and to suggest its suitability for individualized blood pressure management during and after thoracoabdominal aneurysm repair.A 53-year-old man with a history of multiple arch and thoracic aortic procedures underwent staged hybrid treatment of a large TAAA due to chronic dissection from the distal aortic arch into the iliac arteries. During the procedures, near-infrared spectroscopy (NIRS) sensors were applied over the 10th thoracic vertebra for continuous monitoring of tissue oxygen saturation (S(s)O(2)) during endovascular repair. After stent-graft deployment, mean S(s)O(2) decreased significantly. Moreover, the relationship between S(s)O(2) and arterial blood pressure became linear, reflecting pressure dependency of spinal cord perfusion after stent deployment.These data show that NIRS monitors post-endograft changes in S(s)O(2) that were strongly related to arterial blood pressure. Regional NIRS monitoring at the vertebral level may function as a valuable noninvasive guide to the management of blood pressure during thoracoabdominal aneurysm repair, both intra- and postoperatively.
Introduction and Objectives: Kidney autotransplantation can be performed in patients with complex renal or ureteral pathology not suitable for in situ reconstruction, such as renal vasculature anomalies, patients with proximal or long complex ureteral strictures, or complex oncological cases. Robot-assisted surgery allows for a high-quality vascular and ureteral anastomosis and faster patient recovery. Robot-assisted kidney autotransplantation (RAKAT) is performed in two phases: nephrectomy and pelvic transplantation. In-between, extraction of the kidney allows for vascular reconstruction or kidney modification on the bench and safe cold ischemia can be established. If no bench reconstruction is needed, total intracorporeal RAKAT (tiRAKAT) is feasible. One case report in Europe has been described; however, to our knowledge no surgical video is available. Methods: A 58 year-old woman suffered from right mid- and distal ureteral stenosis following pelvic radiotherapy 10 years prior for cervical cancer. A JJ stent was placed, but she suffered from recurrent urinary tract infections, and ultimately a nephrostomy was placed. Renogram demonstrated 43% relative right kidney function. As her bladder volume was low following radiotherapy, no Boari flap was possible and the patient refused life-long nephrostomy or nephrectomy. Therefore, tiRAKAT was performed using the DaVinci Xi system. Results: We describe our surgical technique including a video. Surgical time (skin-to-skin) was 5 h and 45 min. Warm ischemia time was 4 min, cold ischemia 55 min, and rewarming ischemia 15 min. The abdominal catheter and bladder catheter were removed on the first and second postoperative day, respectively. The JJ stent was removed after 4 weeks. The patient suffered from pulmonary embolism on the second postoperative day, for which therapeutic low molecular weight heparin was started. No further complications occurred during the first 90 postoperative days. After 7 months, overall kidney function remained stable, right kidney function dropped non-significantly from 27 to 25.2 mL/min (−6.7%) on renal scintigraphy. Conclusion: We demonstrated feasibility and, for the first time, a surgical video of tiRAKAT highlighting patient positioning, trocar placement, and intracorporeal cold ischemia technique.
The Clavien-Dindo classification is perhaps the most widely used approach for reporting postoperative complications in clinical trials. This system classifies complication severity by the treatment provided. However, it is unclear whether the Clavien-Dindo system can be used internationally in studies across differing healthcare systems in high- (HICs) and low- and middle-income countries (LMICs).This was a secondary analysis of the International Surgical Outcomes Study (ISOS), a prospective observational cohort study of elective surgery in adults. Data collection occurred over a 7-day period. Severity of complications was graded using Clavien-Dindo and the simpler ISOS grading (mild, moderate or severe, based on guided investigator judgement). Severity grading was compared using the intraclass correlation coefficient (ICC). Data are presented as frequencies and ICC values (with 95 per cent c.i.). The analysis was stratified by income status of the country, comparing HICs with LMICs.A total of 44 814 patients were recruited from 474 hospitals in 27 countries (19 HICs and 8 LMICs). Some 7508 patients (16·8 per cent) experienced at least one postoperative complication, equivalent to 11 664 complications in total. Using the ISOS classification, 5504 of 11 664 complications (47·2 per cent) were graded as mild, 4244 (36·4 per cent) as moderate and 1916 (16·4 per cent) as severe. Using Clavien-Dindo, 6781 of 11 664 complications (58·1 per cent) were graded as I or II, 1740 (14·9 per cent) as III, 2408 (20·6 per cent) as IV and 735 (6·3 per cent) as V. Agreement between classification systems was poor overall (ICC 0·41, 95 per cent c.i. 0·20 to 0·55), and in LMICs (ICC 0·23, 0·05 to 0·38) and HICs (ICC 0·46, 0·25 to 0·59).Caution is recommended when using a treatment approach to grade complications in global surgery studies, as this may introduce bias unintentionally.