The expression "developmental hemostasis" indicates the age-related physiological changes occurring during the maturational process of the hemostatic system. Despite the quantitative and qualitative alterations, the neonatal hemostatic system is competent and well-balanced. Conventional coagulation tests do not provide reliable information as they only explore the procoagulants during the neonatal period. In contrast, viscoelastic coagulation tests (VCTs), such as viscoelastic coagulation monitoring (VCM), thromboelastography (TEG or ClotPro), and rotational thromboelastometry (ROTEM), are point-of-care assays that provide a quick, dynamic and global view of the hemostatic process, allowing prompt and individualized therapeutic intervention when necessary. Their use in neonatal care is on the increase and they could help monitor patients at risk of hemostatic derangement. In addition, they are crucial for anticoagulation monitoring during extracorporeal membrane oxygenation. Moreover, implementing VCT-based monitoring could optimize blood product use.
Congenital diaphragmatic hernia is a rare disease with high mortality and morbidity due to pulmonary hypoplasia and pulmonary hypertension. The aim of the study is to investigate the relationship between radiographic lung area and systolic pulmonary artery pressure (sPAP) on the first day of life, mortality, and hernia recurrence during the first year of life in infants with a congenital diaphragmatic hernia (CDH). A retrospective data collection was performed on 77 CDH newborns. Echocardiographic sPAP value, deaths, and recurrence cases were recorded. Lung area was calculated by tracing the lung's perimeter, excluding mediastinal structures, and herniated organs, on the preoperative chest X-ray performed within 24 h after birth. Logistic and linear regression analyses were performed. Deceased infants showed lower areas and higher sPAP values. One square centimeter of rising in the total, ipsilateral, and contralateral area was associated with a 22, 43, and 24% reduction in mortality risk. sPAP values showed a decreasing trend after birth, with a maximum of 1.84 mmHg reduction per unitary increment in the ipsilateral area at birth. Recurrence patients showed lower areas, with recurrence risk decreasing by 14 and 29% per unit increment of the total and ipsilateral area. In CDH patients, low lung area at birth reflects impaired lung development and defect size, being associated with increased sPAP values, mortality, and recurrence risk. Clinical Trial Registration: The manuscript is an exploratory secondary analysis of the trial registered at ClinicalTrials.gov with identifier NCT04396028.
Abstract Background Extremely low gestational age neonates (ELGANs, i.e., neonates born before 28 weeks of gestation) are at high risk of developing retinopathy of prematurity (ROP), with potential long-life visual impairment. Due to concomitant anemia, ELGANs need repeated red blood cell (RBC) transfusions. These produce a progressive replacement of fetal hemoglobin (HbF) by adult hemoglobin (HbA). Furthermore, a close association exists between low levels of HbF and severe ROP, suggesting that a perturbation of the HbF-mediated oxygen release may derange retinal angiogenesis and promote ROP. Methods/design BORN (umBilical blOod to tRansfuse preterm Neonates) is a multicenter double-blinded randomized controlled trial in ELGANs, to assess the effect of allogeneic cord blood RBC transfusions (CB-RBCs) on severe ROP development. Recruitment, consent, and randomization take place at 10 neonatology intensive care units (NICUs) of 8 Italian tertiary hospitals. ELGANs with gestational age at birth comprised between 24+0 and 27+6 weeks are randomly allocated into two groups: (1) standard RBC transfusions (adult-RBCs) (control arm) and (2) CB-RBCs (intervention arm). In case of transfusion need, enrolled patients receive transfusions according to the allocation arm, unless an ABO/RhD CB-RBC is unavailable. Nine Italian public CB banks cooperate to make available a suitable amount of CB-RBC units for all participating NICUs. The primary outcome is the incidence of severe ROP (stage 3 or higher) at discharge or 40 weeks of postmenstrual age, which occurs first. Discussion BORN is a groundbreaking trial, pioneering a new transfusion approach dedicated to ELGANs at high risk for severe ROP. In previous non-randomized trials, this transfusion approach was proven feasible and able to prevent the HbF decrease in patients requiring multiple transfusions. Should the BORN trial confirm the efficacy of CB-RBCs in reducing ROP severity, this transfusion strategy would become the preferential blood product to be used in severely preterm neonates. Trial registration ClinicalTrials.gov NCT05100212. Registered on October 29, 2021
Abstract Background Particulate contamination due to infusion therapy (administration of parenteral nutrition and medications) carries a potential health risk for infants in neonatal intensive care units (NICUs). This particulate consists of metals, drug crystals, glass fragments, or cotton fibers and can be generated by drug packaging, incomplete reconstitution, and chemical incompatibilities. In-line filters have been shown to remove micro-organisms, endotoxin, air, and particles in critically ill adults and older infants, but its benefits in newborn remain to be demonstrated. Moreover, 50% of inflammatory episodes in the setting of NICUs are blood culture-negative. These episodes could be partly related to the presence of particles in the infusion lines. Methods A multicenter randomized single-blind controlled trial was designed. All infants admitted to NICUs for which prolonged infusion therapy is expected will be enrolled in the study and randomized to the Filter or Control arm. All patients will be monitored until discharge, and data will be analyzed according to a “full analysis set.” The primary outcome is the frequency of patients with at least one sepsis-like event, defined by any association of suspected sepsis symptoms with a level of c-reactive protein (CRP) > 5 mg/L in a negative-culture contest. The frequency of sepsis, phlebitis, luminal obstruction, and the duration of mechanical ventilation and of catheter days will be evaluated as secondary outcomes. The sample size was calculated at 368 patients per arm. Discussion This is the first multicenter randomized control trial that compares in-line filtration of parenteral nutrition and other intravenous drugs to infusion without filters. Sepsis-like events are commonly diagnosed in clinical practice and are more frequent than sepsis in a positive culture contest. The risk of these episodes in the target population is estimated at 30–35%, but this data is not confirmed in the literature. If the use of in-line filters results in a significant decrease in sepsis-like events and/or in any other complications, the use of in-line filters in all intravenous administration systems may be recommended in NICUs. Trial registration ClinicalTrials.gov, NCT05537389, registered on 12 September 2022 ( https://classic.clinicaltrials.gov/ct2/show/results/NCT05537389?view=results ).
We aimed to evaluate the policies and practices about neonatal resuscitation in a large sample of European hospitals.This was a cross-sectional electronic survey. A 91-item questionnaire focusing on the current delivery room practices in neonatal resuscitation domains was individually sent to the directors of 730 European neonatal facilities or (in 5 countries) made available as a Web-based link. A comparison was made between hospitals with ≤2,000 and those with >2,000 births/year and between hospitals in 5 European areas (Eastern Europe, Italy, Mediterranean countries, Turkey, and Western Europe).The response rate was 57% and included participants from 33 European countries. In 2018, approximately 1.27 million births occurred at the participating hospitals, with a median of 1,900 births/center (interquartile range: 1,400-3,000). Routine antenatal counseling (p < 0.05), the presence of a resuscitation team at all deliveries (p < 0.01), umbilical cord management (p < 0.01), practices for thermal management (p < 0.05), and heart rate monitoring (p < 0.01) were significantly different between hospitals with ≤2,000 births/year and those with >2,000 births/year. Ethical and educational aspects were similar between hospitals with low and high birth volumes. Significant variance in practice, ethical decision-making, and training programs were found between hospitals in 5 different European areas.Several recommendations about available equipment and clinical practices recommended by the international guidelines are already implemented by centers in Europe, but a large variance still persists. Clinicians and stakeholders should consider this information when allocating resources and planning European perinatal programs.
Viscoelastic coagulation tests provide valuable information in neonatal intensive care units (NICUs), but the lack of reference intervals still limits their decision-making power according to gestational age. The aim of the present study is to evaluate the hemostasis of a cohort of full-term (FT) and late-preterm (LP) infants using the viscoelastic coagulation monitor (VCM®) system, a new portable device that uses untreated whole blood.An observational study was performed to identify non-coagulopathic FT and LP infants admitted to III° level NICU (January 2020 to December 2021) with a VCM test in the first 72 h of life.Forty-five patients were enrolled, 26 FT and 19 LP. No statistical differences in hemostatic parameters were observed between FT and LP nor between stable and unstable neonates. Clotting time (CT) was positive correlated with PT (p = 0.032), not with aPTT (p = 0.185). From linear regression, platelet resulted associated with: clot formation time (CTF, p = 0.003), alpha angle (Alpha, p = 0.010), amplitude at 10 (A10, p = 0.001), amplitude at 20 min (A20, p < 0.001), maximum clot firmness (MCF, p < 0.001); and fibrinogen was associated with: A10 (p = 0.008), A20 (p = 0.015) and MCF (p = 0.024). Compared to the adult reference population, neonates showed shorter CT (mean (SD): 5.3 (1.4) vs. 7.0 (0.9) min, p < 0.001), CFT (2.4 (0.7) vs. 2.8 (0.6) minutes, p < 0.001) and higher Alpha (60.8 (6.3) vs. 55 (5)°, p < 0.001). In addition, the neonatal cohort showed an early transient difference in amplitude and fibrinolysis, as follows: A10 (28.0 (5.0) vs. 26 (4) VCM units, p =0.004), A20 (34.8 (5.0) vs. 33 (4) VCM units, p =0.012), and LI30 (99.8 (0.5) vs. 99 (1)%, p <0.001).The viscoelastic profile of FT and LP infants assessed with VCM showed a hemostatic competence characterized by accelerated coagulation and clot formation time, in line with other viscoelastic techniques. VCM system provides promising applications in the NICU setting.
Preterm extremely low birth weight infants (ELBWi) are known to be at greater risk of developing neuropsychiatric diseases. Identifying early predictors of outcome is essential to refer patients for early intervention. Few studies have investigated neurodevelopmental outcomes in Italian ELBWi. This study aims to describe neurodevelopmental outcome at 24 months of corrected age in an eleven-year single-center cohort of Italian ELBWi and to identify early risk factors for adverse neurodevelopmental outcomes.All infants born with birth weight < 1000 g and admitted to the Neonatal Intensive Care Unit of the "Fondazione IRCCS Policlinico San Matteo" hospital in Pavia, Italy, from Jan 1, 2005 to Dec 31, 2015 were eligible for inclusion. At 24 months, Griffiths' Mental Developmental Scales Extended Revised (GMDS-ER) were administered. Neurodevelopmental outcome was classified as: normal, minor sequelae (minor neurological signs, General Quotient between 76 and 87), major sequelae (cerebral palsy; General Quotient ≤ 75; severe sensory impairment). Univariate and multivariate multinomial logistic regression models were performed to analyze the correlation between neonatal variables and neurodevelopmental outcome.176 ELBWi were enrolled (mean gestational age 26.52 weeks sd2.23; mean birthweight 777.45 g sd142.89). 67% showed a normal outcome at 24 months, 17% minor sequelae and 16% major sequelae (4.6% cerebral palsy on overall sample). The most frequent major sequela was cognitive impairment (8.52%). In the entire sample the median score on the Hearing-Speech subscale was lower than the median scores recorded on the other subscales and showed a significantly weaker correlation to each of the other subscales of the GMDS-ER. Severely abnormal cUS findings (RRR 10.22 p 0.043) and bronchopulmonary dysplasia (RRR 4.36 p 0.008) were independent risk factors for major sequelae and bronchopulmonary dysplasia for minor sequelae (RRR 3.00 p 0.018) on multivariate multinomial logistic regression.This study showed an improvement in ELBWI survival rate without neurodevelopmental impairment at 24 months compared to previously reported international cohorts. Cognitive impairment was the most frequent major sequela. Median scores on GMDS-ER showed a peculiar developmental profile characterized by a selective deficit in the language domain. Severely abnormal cUS findings and bronchopulmonary dysplasia were confirmed as independent risk factors for major sequelae.
Background Preterm newborns receiving briefly delayed cord clamping or cord milking at birth have better neonatal outcomes. However, the time frame in which both these procedures are performed (90% of infants receiving echographic assessments in the first 24 h) and safety variables (5 min Apgar score, delivery room intubation rate, CRIB II score, admission temperature, maximum hemoglobin concentration and hematocrit in the first 24 h and maximum serum bilirubin value) in the two study groups. We also evaluated the same safety variables in infants delivered during the study period but not recruited. Results A total of 40 infants were enrolled. In all cases the protocol was completed and all feasibility outcomes were reached. Infants assisted with an intact placental circulation have a higher 5 min Apgar score but their admission temperature was lower than milked infants. Delivery room intubation rate, CRIB II score and peak serum bilirubin value were comparable in both groups. Infants who were not subjected to a placental transfusion strategy (excluded patients) had a higher delivery room intubation rate with respect to both study groups. Conclusion Delaying cord clamping until 3 min of life was challenging but feasible and appeared to be safe. However, admission temperature must be strictly monitored and a more efficacious warming system could be implemented to prevent hypothermia during the procedure.