Our patient was a 50-year-old woman with tricuspid atresia who had undergone palliation with a Potts shunt to the left pulmonary artery as an infant and a classic Glenn shunt to the right pulmonary artery as a young child. Under general anesthesia, she underwent transcatheter edge-to-edge repair of the mitral valve for severe symptomatic mitral regurgitation. (Level of Difficulty: Advanced.).
Bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and laceration of the anterior mitral leaflet to prevent outflow obstruction (LAMPOON) reduce the risk of coronary and left ventricular outflow obstruction obstruction during transcatheter aortic valve replacement and transcatheter mitral valve replacement. Despite successful laceration, BASILICA or LAMPOON may fail to prevent obstruction caused by inadequate leaflet splay in patients having challenging anatomy such as very small valve-to-coronary distance, diffusely calcified, rigid leaflets, or undergoing transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement. We describe a novel technique of balloon-augmented (BA) leaflet laceration to enhance leaflet splay.We measured the incremental leaflet splay from BA-BASILICA in vitro. From November 2019 to March 2021, 16 patients underwent BA-BASILICA and 4 BA-LAMPOON at 3 centers.BA-BASILICA increased benchtop leaflet tip splay 17%, maximum splay angle 30%, and splay area 23%, resulting in a more rounded apex and larger effective area. Sixteen patients at risk for inadequate BASILICA leaflet splay, including 4 transcatheter aortic valve replacement inside existing transcatheter aortic valve replacement, underwent BA-BASILICA. All had successful leaflet laceration. One had coronary obstruction requiring immediate orthotopic stenting. Two underwent elective orthotopic coronary stenting through the transcatheter valve cells for leaflet prolapse without coronary ischemia. There were no deaths during the procedure or at 30 days. Four patients at risk for inadequate anterior mitral leaflet splay underwent BA-LAMPOON. All had successful target leaflet laceration without left ventricular outflow obstruction obstruction or procedural death. One died within 30 days.BA leaflet laceration enhances leaflet splay in vitro and may allow transcatheter aortic valve replacement and transcatheter mitral valve replacement in patients otherwise ineligible for traditional BASILICA or LAMPOON due to challenging anatomy. Graphic Abstract: A graphic abstract is available for this article.
Patient safety event (PSE) reporting is a critical element for healthcare organizations that are striving for continuous quality improvement. Although resident physicians routinely provide the majority of direct patient care, the level of their participation in PSE reporting historically has been low. In addition, as part of the Accreditation Council for Graduate Medical Education's Next Accreditation System, the Clinical Learning Environment Review site visit assesses residents' engagement in PSE reporting at each accredited academic institution. The objective of this study was to understand the common barriers to PSE reporting and design an intervention to increase the number of PSE reports by resident physicians.We surveyed 304 residents and fellows to assess attitudes toward the PSE reporting system and identify barriers to submitting online PSE reports. Based on this analysis of barriers, we piloted interventions with the internal medicine residency program and measured their effect on resident PSE reporting.Of the survey respondents, 58% had never submitted a PSE report. The most commonly identified barriers were too much time required to submit a report (38% of all respondents), lack of education on how or what to report (37%), lack of feedback or change after reporting (19%), and concern for repercussions or lack of anonymity (13%). Based on this analysis of barriers, we piloted interventions with the internal medicine residency program to educate residents about PSE reporting through a reminder message in their orientation e-mail, informational slides at the end of conferences that described what and how to report, a pocket card with reporting instructions, and leadership encouragement during walk rounds by chief medical residents and the program director. Compared with the 10 weeks before the start of the intervention, the number of PSE reports submitted by internal medicine residents more than doubled, from 16 to 37 reports (P < 0.01). This increase in resident PSE reporting was sustained for 20 weeks despite the interventions lasting only 8 weeks.A resident-driven intervention that fostered a culture of encouragement for PSE reporting through leadership support and targeted education increased the number of PSE reports submitted by internal medicine residents at our health system. Hospitals and health systems should seek to understand the common barriers to PSE reporting from this important group of direct patient care providers and administer structured educational programs to encourage their participation.
A clinical study comparing the hemodynamic outcomes of transcatheter mitral valve replacement (TMVR) with vs. without Laceration of the Anterior Mitral leaflet to Prevent Outflow Obstruction (LAMPOON) has never been designed nor conducted.To quantify the hemodynamic impact of LAMPOON in TMVR using patient-specific computational (in silico) models.Eight subjects from the LAMPOON investigational device exemption trial were included who had acceptable computed tomography (CT) data for analysis. All subjects were anticipated to be at prohibitive risk of left ventricular outflow tract (LVOT) obstruction from TMVR, and underwent successful LAMPOON immediately followed by TMVR. Using post-procedure CT scans, two 3D anatomical models were created for each subject: (1) TMVR with LAMPOON (performed procedure), and (2) TMVR without LAMPOON (virtual control). A validated computational fluid dynamics (CFD) paradigm was then used to simulate the hemodynamic outcomes for each condition.LAMPOON exposed on average 2 ± 0.6 transcatheter valve cells (70 ± 20 mm2 total increase in outflow area) which provided an additional pathway for flow into the LVOT. As compared to TMVR without LAMPOON, TMVR with LAMPOON resulted in lower peak LVOT velocity, lower peak LVOT gradient, and higher peak LVOT effective orifice area by 0.4 ± 0.3 m/s (14 ± 7% improvement, p = 0.006), 7.6 ± 10.9 mmHg (31 ± 17% improvement, p = 0.01), and 0.2 ± 0.1 cm2 (17 ± 9% improvement, p = 0.002), respectively.This was the first study to permit a quantitative, patient-specific comparison of LVOT hemodynamics following TMVR with and without LAMPOON. The LAMPOON procedure achieved a critical increment in outflow area which was effective for improving LVOT hemodynamics, particularly for subjects with a small neo-left ventricular outflow tract (neo-LVOT).