Four-dimensional computed tomography (4DCT: three dimensional + time) allows to measure individual bone position over a period of time usually during motion. This method has been found useful in st...
Polycystic liver disease (PLD) is characterized by growth of hepatic cysts, causing hepatomegaly. Disease severity is determined using total liver volume (TLV), which can be measured from computed tomography (CT). The gold standard is manual segmentation which is time-consuming and requires expert knowledge of the anatomy. This study aims to validate the commercially available semi-automatic MMWP (Multimodality Workplace) Volume tool for CT scans of PLD patients.We included adult patients with one (n = 60) or two (n = 46) abdominal CT scans. Semi-automatic contouring was compared with manual segmentation, using comparison of observed volumes (cross-sectional) and growth (longitudinal), correlation coefficients (CC), and Bland-Altman analyses with bias and precision, defined as the mean difference and SD from this difference. Inter- and intra-reader variability were assessed using coefficients of variation (CV) and we assessed the time to perform both procedures.Median TLV was 5292.2 mL (IQR 3141.4-7862.2 mL) at baseline. Cross-sectional analysis showed high correlation and low bias and precision between both methods (CC 0.998, bias 1.62%, precision 2.75%). Absolute volumes were slightly higher for semi-automatic segmentation (manual 5292.2 (3141.4-7862.2) versus semi-automatic 5432.8 (3071.9-7960.2) mL, difference 2.7%, p < 0.001). Longitudinal analysis demonstrated that semi-automatic segmentation accurately measures liver growth (CC 0.908, bias 0.23%, precision 4.04%). Inter- and intra-reader variability were small (2.19% and 0.66%) and comparable to manual segmentation (1.21% and 0.63%) (p = 0.26 and p = 0.37). Semi-automatic segmentation was faster than manual tracing (19 min versus 50 min, p = 0.009).Semi-automatic liver segmentation is a fast and accurate method to determine TLV and liver growth in PLD patients.• Semi-automatic liver segmentation using the commercially available MMWP volume tool accurately determines total liver volume as well as liver growth over time in polycystic liver disease patients. • This method is considerably faster than manual segmentation through the use of Hounsfield unit settings. • We used a real-life CT set for the validation and showed that the semi-automatic tool measures accurately regardless of contrast used for the CT scan or not, presence of polycystic kidneys, liver volume, and previous invasive treatment for polycystic liver disease.
Programmable shunt valve settings can sometimes be difficult to assess using classic read-out tools, warranting a skull X-ray.Can we use available head computed tomography (CT) scans to determine the valve settings, in order to obviate the need for additional skull X-rays?The valve setting of two different programmable shunts (Codman Certas Plus® and Sophysa Polaris®) were assessed by two blinded observers in 24 patients using 65 head CT scans (slice thickness ≤2 mm). Using multi-planar reconstruction (MPR) tools, images were resliced according to the direction of the valve, allowing a direct readout of the valve settings. We validated our CT based method against 32 available skull X-rays.For all CT scans it was possible to assess the valve setting. No interobserver variability was found and there was a 100 % concordance between the CT based method and skull X-rays.CT based assessment of programmable shunt valve settings is feasible and reliable. It may obviate the need for additional skull x-rays when a head CT scan is available.This technique can reduce radiation exposure and can be applied to historical CT imaging with unknown valve settings.
Left ventricular (LV) dilatation results in increased sphericity and affects position and orientation of papillary muscles (PMs), which may influence their performed work. The aim of this study was to assess the contribution of PM to LV function and its changes with dilatation.Fifteen sheep were investigated. Ten animals were subjected to 8 weeks of rapid (180 bpm) pacing, inducing LV dilatation. Five animals served as controls. High-resolution gated computed tomography was performed to assess LV volumes, left ventricular ejection fraction (LVEF), global longitudinal strain (GLS), sphericity index, and PM angle, width and fractional shortening. 18F-fluorodeoxyglucose positron emission tomography (PET) was used to measure glucose metabolism as surrogate of regional myocardial work. Spatial resolution of PET images was maximized by electrocardiogram- and respiratory-gating. 18F-fluorodeoxyglucose uptake was measured in PM and compared with remaining left ventricular myocardium (MYO) to obtain a PM/MYO ratio. Animals with dilated heart had a more spherical left ventricle, with reduced LVEF (P < 0.0001) and GLS (P < 0.0001). In dilated hearts, PET analysis revealed a higher contribution of both PM to LV myocardial work (P < 0.0001); and PM angle towards LV wall correlated with PM work, together with PM width and the LV sphericity index. Sphericity index and posterior PM angle were strongest determinants of posterior PM/MYO ratio (R2 = 0.754; P < 0.0001), while anterior PM/MYO was mostly determined by sphericity index and the PM width (R2 = 0.805; P < 0.0001).In dilated hearts, PM contribute relatively more to LV myocardial work. We hypothesize that this is caused by the more cross-sectional orientation of the subvalvular apparatus, which leads to a higher stress on the PM compared with the spherical LV walls. The reduced cross-sectional area of the PM may further explain their increased stress.
Four-dimensional computed tomography (4DCT: three dimensional + time) allows to measure individual bone position over a period of time usually during motion. This method has been found useful in studying the joints around the wrist as dynamic instabilities are difficult to detect during static CT scans while they can be diagnosed using a 4DCT scan [1]–[3]. For the foot, the PedCAT system (Curvebeam, Warrington, USA) has been developed to study the foot bones under full weight bearing, however its use is limited to static images. On the contrary, dynamic measurements of the foot kinematics using skin markers can only describe motion of foot segments and not of individual bones. However, the ability to measure individual bone kinematics during gait is of paramount importance as such detailed information could be used to detect instabilities, to evaluate the effect of joint degeneration, to help in pre-operative planning as well as in post-operative evaluation. The overall gait kinematics of two healthy volunteers were measured in a gait analysis lab (Movement Analysis Lab Leuven, Belgium) using a detailed foot-model (Oxford foot model, [4]). The measured plantar-dorsiflexion and in-eversion were used to manipulate their foot during a 4D CT acquisition. The manipulation was performed through a custom made foot manipulator that controls the position and orientation of the foot bed according to input kinematics. The manipulator was compatible with the 4D CT Scanner (Aquilion One, Toshiba, JP), and a sequence of CT scans (37 CT scans over 10 seconds with 320 slices for each scan and a slice thickness of 0.5 mm) was generated over the duration of the simulation. The position of the individual bones was determined using an automatic segmentation routine after which the kinematics of individual foot bones were calculated. To do so, three landmarks were tracked on each bone over time allowing to construct bone-specific coordinate frames. The motion of the foot bed was compared against the calculated kinematics of the tibia-calcaneus as the angles between these two bones are captured with skin markers. There is high repeatability between the imposed plantar/dorsiflexion and inversion/eversion and the calculated. Although the internal/external rotation was not imposed, the calculated kinematics follow the same pattern as the measured in the gait-analysis lab. Based on the validation of the tibia-calcaneus, the kinematics were also calculated between four other joints: tibia-talar, talar-calcaneus, calcaneus-cuboid and talar-navicular. Repeatable measurements of individual foot bone motion were obtained for both volunteers. The use of 4D CT-scanning in combination with a foot manipulator can provide more detailed information than skin marker-based gait-analysis e.g. for the study of the the tibia-talar joint. In the future, the foot manipulator will be tested for its sensitivity for specific pathologies (e.g. metatarsal coalition) and will be further developed to better resemble a real-life stance phase of gait (i.e. to include isolated heel contact and toe off).