The Michigan peripherally inserted central catheter-associated bloodstream infection score (MPC score) had been developed for hospitalized medical patients but had not been externally validated. A retrospective analysis of a clinically heterogeneous case-mix in a university hospital cohort in Japan failed to validate its originally reported good performance.
In patients with fever or inflammation of unknown origin (fever of unknown origin [FUO] or inflammation of unknown origin [IUO], respectively), expert consensus recommends the use of positron emission tomography with fluorine-18-fluorodeoxy glucose combined with computed tomography (FDG-PET/CT) when standard work-up fails to identify diagnostic clues. However, the clinical variables associated with successful localization of the cause by FDG-PET/CT remain uncertain. Moreover, the long-term outcomes of patients with unexplained FUO or IUO after negative FDG-PET/CT results are unknown. Therefore, we assessed predictors of successful diagnosis of FUO or IUO caused by FDG-PET/CT and associations of spontaneous remission of symptoms with FDG-PET/CT results.All patients with FUO or IUO, who underwent FDG-PET/CT from 2013 to 2019 because diagnostic work-up failed to identify a cause, were retrospectively included. We calculated the diagnostic yield and performed multivariable logistic regression to assess characteristics previously proposed to be associated with successful localization of FUO or IUO causes. We also assessed whether the FDG-PET/CT results were associated with spontaneous remissions.In total, 50 patients with diagnostically challenging FUO or IUO (35 with FUO and 15 with IUO) were assessed. Other than one case of infection, all the identified causes were either malignancy or non-infectious inflammatory diseases (each with 18 patients), and FDG-PET/CT correctly localized the cause in 29 patients (diagnostic yield = 58%). None of the proposed variables was associated with successful localization. All 13 patients with sustained unexplained cause remained alive (median follow-up, 190 days). Spontaneous remission was observed in 4 of 5 patients with a negative FDG-PET/CT, and 1 of 8 with a positive result (P = 0.018).In the current cohort, the proposed variables were not predictive for successful localization by FDG-PET/CT. A negative FDG-PET/CT scan may be prognostic for spontaneous remission in patients with sustained FUO or IUO.
The Bethesda system (TBS) has been used for cervical cytological diagnosis in Japan since 2008. Evaluation of specimen adequacy is the most important aspect of quality assurance and for precise diagnosis in TBS. A systematic review and meta-analysis were carried out to assess the unsatisfactory specimen rate in the primary cervical cancer screening setting in Japan. Ovid Medline and Ichushi-Web databases were searched from inception through to May 2017. Prospective and retrospective studies that reported the proportion of unsatisfactory specimens in healthy asymptomatic Japanese women in a cervical cancer screening program were eligible for inclusion; 17 studies were included in the meta-analysis. The random-effects model meta-analysis calculated summary estimates of the unsatisfactory rate of 0.60% (95% confidence interval [CI], 0.18-1.96%; I2 = 99%) for conventional cytology and 0.04% (95% CI, 0.00-0.35%; I2 = 99%) for liquid-based cytology (LBC). However, comparative results between conventional and liquid-based cytology, based on four direct and nine comparative studies, showed no significant difference (summary odds ratio = 3.5 × 10-2 favoring LBC [95% CI, 6.9 × 10-4 -1.7]; I2 = 98%). In the subgroup analyses and meta-regressions, use of non-cotton devices for conventional cytology and use of a particular platform for LBC were associated with lower unsatisfactory rates. Meta-regression also suggested chronological improvement in unsatisfactory rates for both tests. In Japanese cervical cancer screening programs, conventional cytology remains prevalent. Future research needs to focus on evaluating the impact of screening programs using LBC by comparing the accuracy, performance, and cost-effectiveness with conventional cytology in the Japanese population.