Bicuspid aortic valve (BAV) is a congenital defect affecting 1–2% of the general population that is distinguished from the normal tricuspid aortic valve (TAV) by the existence of two, rather than three, functional leaflets (or cusps). BAV presents in different morphologic phenotypes based on the configuration of cusp fusion. The most common phenotypes are Type 1 (containing one raphe), where fusion between right coronary and left coronary cusps (BAV R/L) is the most common configuration followed by fusion between right coronary and non-coronary cusps (BAV R/NC). While anatomically different, BAV R/L and BAV R/NC configurations are both associated with abnormal hemodynamic and biomechanical environments. The natural history of BAV has shown that it is not necessarily the primary structural malformation that enforces the need for treatment in young adults, but the secondary onset of premature calcification in ~50% of BAV patients, that can lead to aortic stenosis. While an underlying genetic basis is a major pathogenic contributor of the structural malformation, recent studies have implemented computational models, cardiac imaging studies, and bench-top methods to reveal BAV-associated hemodynamic and biomechanical alterations that likely contribute to secondary complications. Contributions to the field, however, lack support for a direct link between the external valvular environment and calcific aortic valve disease in the setting of BAV R/L and R/NC BAV. Here we review the literature of BAV hemodynamics and biomechanics and discuss its previously proposed contribution to calcification. We also offer means to improve upon previous studies in order to further characterize BAV and its secondary complications.
Abstract The opening and closing dynamics of the aortic valve (AV) has a strong influence on haemodynamics in the aortic root, and both play a pivotal role in maintaining normal physiological functions of the valve. The aim of this study was to establish a subject‐specific fluid–structure interaction (FSI) workflow capable of simulating the motion of a tricuspid healthy valve and the surrounding haemodynamics under physiologically realistic conditions. A subject‐specific aortic root was reconstructed from magnetic resonance (MR) images acquired from a healthy volunteer, whilst the valve leaflets were built using a parametric model fitted to the subject‐specific aortic root geometry. The material behaviour of the leaflets was described using the isotropic hyperelastic Ogden model, and subject‐specific boundary conditions were derived from 4D‐flow MR imaging (4D‐MRI). Strongly coupled FSI simulations were performed using a finite volume‐based boundary conforming method implemented in FlowVision. Our FSI model was able to simulate the opening and closing of the AV throughout the entire cardiac cycle. Comparisons of simulation results with 4D‐MRI showed a good agreement in key haemodynamic parameters, with stroke volume differing by 7.5% and the maximum jet velocity differing by less than 1%. Detailed analysis of wall shear stress (WSS) on the leaflets revealed much higher WSS on the ventricular side than the aortic side and different spatial patterns amongst the three leaflets.
Significance Wirelessly controlled, multitasking soft devices active in aqueous environments are highly required for applications in microfluidics and organ-on-a-chip and as medical devices. Inspired by marine organisms, we present an approach to achieve such devices by utilizing stimuli-responsive material assemblies capable of untethered object manipulation in an enclosed aqueous environment. Our soft robot assembly integrates a magnetically controlled stem with a light-responsive gripper with unmatched speed, insensitivity to contaminants, and high control of actuation underwater at low light intensities. The independent device segments can be orthogonally controlled to realize different tasks such as attracting, capturing, and releasing targets in an aqueous environment, demonstrating the significance of actuator assemblies in the fabrication of multifunctional soft devices operating underwater.
The aim of this study was to assess the haemodynamic performance of a patient-specific Fenestrated Stent-Graft (FSG) under different physiological conditions, including normal resting, hypertension, and hypertension with moderate lower limb exercise. A patient-specific FSG model was constructed from computed tomography images and was discretised into a fine unstructured mesh comprising of tetrahedral and prism elements. Blood flow was simulated using Navier-Stokes equations and physiologically realistic boundary conditions were utilised to yield clinically relevant results. For a given cycle-averaged inflow of 2.08 L/min at normal resting and hypertension conditions, approximately 25% of flow was channelled into each renal artery. When hypertension was combined with exercise, the cycle-averaged inflow increased to 6.39 L/min but only 6.29% of this was channelled into each renal artery which led to a 438.46% increase in the iliac flow. For all the simulated scenarios and throughout the cardiac cycle, the instantaneous flow streamlines in the FSG were well organised without any notable flow recirculation. This well organised flow led to low values of Endothelial Cell Activation Potential (ECAP), which is a haemodynamic metric used to identify regions at risk of thrombosis. The displacement forces acting on the FSG varied with the physiological conditions and the cycle-averaged displacement force at normal rest, hypertension, and hypertension with exercise was 6.46 N, 8.77 N and 8.99 N, respectively. The numerical results from this study suggest that the analysed FSG can maintain sufficient blood perfusion to the end organs at all the simulated conditions. Even though the FSG was found to have a low risk of thrombosis at rest and hypertension, this risk can be reduced even further with moderate lower limb exercise.
To quantify the hemodynamic impact of a flared renal stent on the performance of fenestrated stent-grafts (FSGs) by analyzing flow patterns and wall shear stress-derived parameters in flared and nonflared FSGs in different physiologic scenarios.
Purpose: To report a computational study assessing the hemodynamic outcomes of branched stent-grafts (BSGs) for different anatomic variations. Methods: Idealized models of BSGs and fenestrated stent-grafts (FSGs) were constructed with different visceral takeoff angles (ToA) and lateral aortic neck angles. ToA was defined as the angle between the centerlines of the main stent-graft and side branch, with 90° representing normal alignment, and 30° and 120° representing angulated side branches. Computational simulations were performed by solving the conservation equations governing the blood flow under physiologically realistic conditions. Results: The largest renal flow recirculation zones (FRZs) were observed in FSGs at a ToA of 30°, and the smallest FRZ was also found in FSGs (at a ToA of 120°). For straight-neck stent-grafts with a ToA of 90°, mean flow in each renal artery was 0.54, 0.46, and 0.62 L/min in antegrade BSGs, retrograde BSGs, and FSGs, respectively. For angulated stent-grafts, the corresponding values were 0.53, 0.48, and 0.63 L/min. All straight-neck stent-grafts experienced equal cycle-averaged displacement forces of 1.25, 1.69, and 1.95 N at ToAs of 30°, 90°, and 120°, respectively. Angulated main stent-grafts experienced an equal cycle-averaged displacement force of 3.6 N. Conclusion: The blood flow rate in renal arteries depends on the configuration of the stent-graft, with an FSG giving maximum renal flow and a retrograde BSG resulting in minimum renal flow. Nevertheless, the difference was small, up to 0.09 L/min. Displacement forces exerted on stent-grafts are very sensitive to lateral neck angle but not on the configuration of the stent-graft.