Alveolar echinococcosis (AE), caused by Echinococcus multilocularis, is an aggressive and potentially critical infestation that primarily affects the liver and can metastasize to any part of the body. We herein report two cases of echinococcosis, which could be differentiated from malignancy on imaging studies, with infections of the liver and mediastinal lymph nodes, and also associated with systemic disseminated lesions. AE is a very invasive infectious disease, and in order to detect such lesions at an early stage when they are still resectable, it is necessary to understand the characteristic imaging findings and determine the patient's current medical history.
Abstract Background and Aim Endoscopic ultrasound‐guided gastroenterostomy is a procedure used to connect the stomach and dilated afferent loop using a stent under endoscopic ultrasound for afferent loop syndrome. However, the actual efficacy and safety of this procedure remain unclear. Therefore, this retrospective study aimed to evaluate the efficacy and safety of endoscopic ultrasound‐guided gastroenterostomy using a laser‐cut‐type fully covered self‐expandable metallic stent and an anchoring plastic stent for afferent loop syndrome. Methods Technical and clinical success rates, adverse events, recurrent intestinal obstruction rates, time to recurrent intestinal obstruction, and technical and clinical success rates of re‐intervention were evaluated in intended patients who underwent endoscopic ultrasound‐guided gastroenterostomy for afferent loop syndrome from October 2018 to August 2022. Results In 25 intended patients with afferent loop syndrome who intended endoscopic ultrasound‐guided gastroenterostomy, the technical success rate was 100% (25/25), whereas the clinical success rate was 96% (24/25). Two patients experienced grade ≥ 3 early adverse events, including one with intra‐abdominal abscess and one with hypotension. Both events were attributed to intestinal fluid leakage. No late adverse events were observed. The recurrent intestinal obstruction rate was 32% (8/25), and the median time to recurrent intestinal obstruction was 6.5 months (95% confidence interval: 2.8–not available). The technical and clinical success rates of re‐intervention were both 100% (8/8). Conclusions Endoscopic ultrasound‐guided gastroenterostomy using a fully covered self‐expandable metallic stent and an anchoring plastic stent is effective and safe as a treatment procedure for afferent loop syndrome.
Abstract Background and study aims Endoscopic ultrasound-guided hepaticogastrostomy with bridging between the left and right bile ducts is an alternative to endoscopic transpapillary drainage for malignant hilar biliary obstruction. We aimed to analyze the long-term stent patency of endoscopic ultrasound-guided hepaticogastrostomy with bridging. Patients and methods Patients who underwent endoscopic ultrasound-guided hepaticogastrostomy with bridging between April 2018 and July 2023 were retrospectively analyzed. We retrospectively compared the stent patency of these patients with that of the individuals who underwent endoscopic transpapillary drainage-multi-stenting using unmatched (entire) and propensity score-matched cohorts. Results Endoscopic ultrasound-guided hepaticogastrostomy with bridging had a technical success rate of 90% (18/20). Adverse events were minimal. The number of clinical success cases was 17 and 82 for endoscopic ultrasound-guided hepaticogastrostomy with bridging using metallic stent and endoscopic transpapillary drainage-multi-stenting, respectively. The recurrent biliary obstruction rate was 17.6% and 58.5% for endoscopic ultrasound-guided hepaticogastrostomy with bridging and endoscopic transpapillary drainage-multi-stenting, respectively; the median time to recurrent biliary obstruction (days) was significantly longer for endoscopic ultrasound-guided hepaticogastrostomy with bridging in the entire (not reached vs. 104, P=0.03) and propensity score-matched (183 vs. 79, P=0.05) cohorts. The non-recurrent biliary obstruction rate for endoscopic ultrasound-guided hepaticogastrostomy with bridging was 91.6% at 3 and 6 months and 57% at 12 months. Multivariate analyses revealed that endoscopic ultrasound-guided hepaticogastrostomy with bridging contributed to a lower recurrent biliary obstruction incidence (hazard ratio, 0.31, P=0.05) without significant difference. Conclusions Stent patency was significantly better for endoscopic ultrasound-guided hepaticogastrostomy with bridging. However, future prospective studies are needed.
Despite previously reported treatment strategies for nonfunctioning small (≤20 mm) pancreatic neuroendocrine neoplasms (pNENs), uncertainties persist. We aimed to evaluate the surgically resected cases of nonfunctioning small pNENs (NF-spNENs) in a large Japanese cohort to elucidate an optimal treatment strategy for NF-spNENs.
EUS–TA in unresectable pancreatic cancer requires not only a tissue diagnosis but also tissue collection in anticipation of comprehensive genomic profiling. However, the optimal puncture target remains controversial. Therefore, the Primary and Metastatic Lesions in Pancreatic Cancer (PRIMATE) study was designed to clarify the optimal target by comparing the success rates for meeting OncoGuide NCC Oncopanel (NOP) analysis criteria on pre-check primary and metastatic lesion specimens obtained during the same EUS–TA session in patients with invasive pancreatic ductal adenocarcinoma. In this ongoing prospective study, two specimens, each from primary and metastatic lesions, are obtained by EUS–TA (typically using a 19G fine-needle biopsy needle) in patients with invasive pancreatic ductal adenocarcinoma. The primary endpoint is the proportion of EUS–TA specimens that meet NOP analysis criteria during pre-check (i.e., tumor cellularity ≥ 20% and tissue area ≥ 4 mm2), which are then compared between primary and metastatic lesions. This study has been approved by the National Cancer Center Institutional Review Board (Research No. 2022-168). The results of this study will be reported at an international conference and published in an international peer-reviewed journal. The trial registration number is UMIN 000048966.
EUS–TA in unresectable pancreatic cancer requires not only a tissue diagnosis but also tissue collection in anticipation of comprehensive genomic profiling. However, the optimal puncture target remains controversial. Therefore, the Primary and Metastatic Lesions in Pancreatic Cancer (PRIMATE) study was designed to clarify the optimal target by comparing the success rates for meeting OncoGuide NCC Oncopanel (NOP) analysis criteria on pre-check primary and metastatic lesion specimens obtained during the same EUS–TA session in patients with invasive pancreatic ductal adenocarcinoma. In this ongoing prospective study, two specimens, each from primary and metastatic lesions, are obtained by EUS–TA (typically using a 19G fine-needle biopsy needle) in patients with invasive pancreatic ductal adenocarcinoma. The primary endpoint is the proportion of EUS–TA specimens that meet NOP analysis criteria during pre-check (i.e., tumor cellularity of ≥20% and a tissue area of ≥4 mm2), which are then compared between primary and metastatic lesions. This study has been approved by the National Cancer Center Institutional Review Board (Research No. 2022-168). The results of this study will be reported at an international conference and published in an international peer-reviewed journal. The trial registration number is UMIN 000048966.
<b><i>Background:</i></b> The sensitivity of <sup>18</sup>F-fluorodeoxyglucose positron emission tomography/computed tomography (<sup>18</sup>F-FDG-PET/CT) in hepatocellular carcinoma (HCC) is low; however, clinical evidence demonstrating its prognostic value in patients with HCC has recently been reported. This study aimed to assess the value of <sup>18</sup>F-FDG-PET/CT as a tool for evaluating the response of HCC to lenvatinib treatment. <b><i>Methods:</i></b> We evaluated 11 consecutive patients with HCC diagnosed by dynamic CT or magnetic resonance imaging combined with <sup>18</sup>F-FDG-PET/CT from April 2018 to December 2019. The tumor-to-normal liver ratio (TLR) of the target tumor was measured before and during the course of lenvatinib treatment with <sup>18</sup>F-FDG-PET/CT (pre and post analysis, respectively), with a TLR ≥2 classified as PET-positive HCC. At the time of each evaluation, we also used the Response Evaluation Criteria in Solid Tumors (RECIST) 1.1, the modified RECIST (mRECIST), and the tumor marker alfa-fetoprotein (AFP). <b><i>Results:</i></b> Of 11 patients, 3 (27%) and 8 (73%) had an objective response to lenvatinib treatment at the time of post-analysis by RECIST 1.1 and mRECIST, respectively. There were 3 (27%) and 7 (64%) patients with PET-positive HCC at the time of pre- and post-analysis, respectively. There was a significant correlation between the rates of change in AFP and TLR during lenvatinib treatment (<i>r</i> = 0.69, <i>p</i> = 0.019). Based on these results, we were able to perform liver resection on 4 patients with PET-positive HCC as conversion therapy. Three samples from these patients showed poorly differentiated tumors. <b><i>Conclusion:</i></b> <sup>18</sup>F-FDG-PET/CT has potential as an evaluation tool for describing biological tumor behavior and reflecting disease progression, location, and treatment response. This modality may provide useful information for considering prognosis and subsequent therapy.
Endoscopic ultrasound-guided pancreatic duct drainage (EUS-PD) is emerging as an effective alternative treatment for obstructive pancreatitis after unsuccessful endoscopic retrograde pancreatography (ERP). However, the high incidence of adverse events associated with EUS-PD (approximately 20%) remains an issue. Recently, we developed a novel plastic stent for EUS-PD, with a radiopaque marker positioned at approximately one-third of the length from the distal end of the stent and side holes positioned exclusively distal to the marker. This study aimed to evaluate the feasibility and safety of using this stent in EUS-PD.
Background and study aims Recently, the utility of endoscopic ultrasound-guided intervention without fistula dilation (EUS-IV WoD) has been reported to prevent adverse events. We clinically evaluated cases in which EUS-IV WoD was attempted using a novel self-expandable metallic stent (SEMS); this is a fully covered, laser-cut SEMS that has a tapered and stiff tip specifically designed for a 0.025-inch guidewire and a relatively thin, 7F delivery system. Patients and methods We retrospectively evaluated cases wherein EUS-IV WoD was attempted using the novel SEMS between March and December 2021. Results Treatment of 11 patients by EUS-IV WoD with the novel SEMS was attempted. The technical success rate for EUS-IV was 100 % and the clinical success rate was 100 %; the success rate for EUS-IV WoD was 72.8 %. Of these, the procedural success rate for EUS-IV WoD was 100 % in EUS-biliary drainage (BD) and 57.1 % in non-EUS-BD. Early adverse events were observed in 27.3 % of patients (3/11): mild abdominal pain in two patients and moderate bleeding in one patient. The abdominal pain cases were both cases of EUS-IV WoD failure and required fistula dilation. Conclusions The novel stent may be useful for EUS-IV WoD, especially in EUS-BD.