Bone metastases cause pain, suffering and impaired quality of life (QoL). Palliative radiotherapy (RT) and/or chemotherapy are effective methods in controlling pain, reducing analgesics use and improving QoL. This study goal was to investigate the changes in QoL scores among patients who responded to palliative treatment.A prospective study evaluating the role of radiation therapy in a public academic hospital in São Paulo-Brazil recorded patients' opioid use, pain score, Portuguese version of QLQ-BM22 and QLQ-C30 before and 2 months after radiotherapy. Analgesic use and pain score were used to calculate international pain response category. Overall response was defined as the sum of complete response (CR) and partial response (PR). CR was defined as pain score of 0 with no increase in analgesic intake whereas PR was defined as pain reduction ≥2 without analgesic increase or analgesic reduction in ≥25% without increase in pain at the treated site.From September 2014 to October 2015, 25 patients with bone metastases responded to RT or chemotherapy (1 CR, 24 PR). There were 8 male and 17 female patients. The median age of the 25 patients was 59 (range, 22 to 80) years old. Patient's primary cancer site was breast [11], prostate [5], lung [2], others [7]. For QLQ-BM 22, the mean scores of 4 categories at baseline were: pain site (PS) 39, pain characteristics (PC) 61, function interference (FI) 49 and psycho-social aspects (PA) 57. At 2 month follow up, the scores were PS 27, PC 37, FI 70 and PA 59. Statistical significant improvement (P<0.05) was seen in PS, PC, FI but not PA. In the QLQ-C30, the scores were not statistically different for all categories, except for pain that demonstrated a 33 point decrease in the median pain score domain (66 to 33).Responders to RT at 2 months presented improvement in BM22 and C30 pain domains, and also improvement in functional interference domain of the BM22 questionnaire.
In this study, we propose combining three-dimensional (3D) transrectal ultrasound (TRUS) and 3D transabdominal ultrasound (TAUS) images of gynecologic brachytherapy applicators to leverage the advantages of each imaging perspective, providing a broader field-of-view and allowing previously obscured features to be recovered. The aim of this study was to evaluate the feasibility of fusing these 3D ultrasound (US) perspectives based on the applicator geometry in a phantom prior to clinical implementation.In proof-of-concept experiments, 3D US images of application-specific multimodality pelvic phantoms were acquired with tandem-and-ring and tandem-and-ovoids applicators using previously validated imaging systems. Two TRUS images were acquired at different insertion depths and manually fused based on the position of the ring/ovoids to broaden the TRUS field-of-view. The phantom design allowed "abdominal thickness" to be modified to represent different body habitus and TAUS images were acquired at three thicknesses for each applicator. The merged TRUS images were then combined with TAUS images by rigidly aligning applicator components and manually refining the registration using the positions of source channels and known tandem length, as well as the ring diameter for the tandem-and-ring applicator. Combined 3D US images were manually, rigidly registered to images from a second modality (magnetic resonance (MR) imaging for the tandem-and-ring applicator and X-ray computed tomography (CT) for the tandem-and-ovoids applicator (based on applicator compatibility)) to assess alignment. Four spherical fiducials were used to calculate target registration errors (TREs), providing a metric for validating registrations, where TREs were computed using root-mean-square distances to describe the alignment of manually identified corresponding fiducials. An analysis of variance (ANOVA) was used to identify statistically significant differences (p < 0.05) between the TREs for the three abdominal thicknesses for each applicator type. As an additional indicator of geometric accuracy, the bladder was segmented in the 3D US and corresponding MR/CT images, and volumetric differences and Dice similarity coefficients (DSCs) were calculated.For both applicator types, the combination of 3D TRUS with 3D TAUS images allowed image information obscured by the shadowing artifacts under single imaging perspectives to be recovered. For the tandem-and-ring applicator, the mean ± one standard deviation (SD) TREs from the images with increasing thicknesses were 1.37 ± 1.35 mm, 1.84 ± 1.22 mm, and 1.60 ± 1.00 mm. Similarly, for the tandem-and-ovoids applicator, the mean ± SD TREs from the images with increasing thicknesses were 1.37 ± 0.35 mm, 1.95 ± 0.90 mm, and 1.61 ± 0.76 mm. No statistically significant difference was detected in the TREs for the three thicknesses for either applicator type. The mean volume differences for the bladder segmentations were 3.14% and 2.33% and mean DSCs were 87.8% and 87.7% for the tandem-and-ring and tandem-and-ovoids applicators, respectively.In this proof-of-concept study, we demonstrated the feasibility of fusing 3D TRUS and 3D TAUS images based on the geometry of tandem-and-ring and tandem-and-ovoids applicators. This represents a step toward an accessible and low-cost 3D imaging method for gynecologic brachytherapy, with the potential to extend this approach to other intracavitary configurations and hybrid applicators.
Abstract Purpose To compare CTV HR and OAR dimensions and inter-rater agreement between magnetic resonance (MR) and trans-rectal ultrasound (TRUS) images in IB cervical cancer patients. Methods IB cervical cancer patients treated with (chemo)radiotherapy plus MR-guided brachytherapy (BT) were prospectively enrolled in this study. Radiation oncologists contoured CTV HR and OARs in pre-BT MR images (MRI) and intra-operative TRUS images. These contours were subsequently compared in regard to volume and dimension. Contour inter-rater agreement analysis was also investigated using kappa index (KI). Stata 15.0 was used for statistical analysis and a p -value < 0.05 was considered statistically significant. Results TRUS CTV HR volumes were statistically smaller than the respective MRI contoured volumes. TRUS CTV HR thickness was found to be consistently smaller than MRI contours in all patients. No statistical difference was seen in width and height between the two different imaging modalities. MRI contours had a median KI of 0.66 (range: 0.56–0.77) while TRUS-based contours had a median KI of 0.64 (range: 0.47–0.77). Bladder and rectum had very satisfactory KI in both imaging modalities. Vaginal contours had moderate agreement in MR (0.52) and in TRUS images (0.58). Conclusion TRUS images allow good visualization of CTV HR and OARs in IB cervical cancer patients. Inter-rater contour variability was comparable between TRUS and MR images. TRUS is a promising modality on its own for image-guided BT.