Introduction: This study was designed to assess whether right ventricular pacing in the implantable cardioverter defibrillator (ICD) arm of the Multicenter Automatic Defibrillator Implantation Trial (MADIT) II was associated with an unfavorable outcome. Methods and Results: Data on the number of ventricular paced beats were available in 567 (76%) of 742 MADIT II patients with ICDs. The number of ventricular paced beats over the total number of beats showed a bimodal distribution with patients being predominantly paced or nonpaced. Therefore, patients were dichotomized at 0–50% and 51–100% of cumulative pacing with median pacing rate 0.2% and 95.6%, respectively. Endpoints included new or worsening heart failure, appropriate ICD therapy for VT/VF, and the combined endpoint of heart failure or death. Clinical features associated with frequent ventricular pacing included age ≥65 years, advanced NYHA heart failure class, LVEF < 0.25, first degree AV and bundle branch block, and amiodarone use. During follow‐up, 119 patients (21%) had new or worsened heart failure, 130 (23%) had new or worsened heart failure or death, and 142 (25%) had appropriate therapy for VT/VF. In comparison to patients with infrequent pacing, those with frequent pacing had significantly higher risk of new or worsened heart failure (hazard ratio = 1.93; P = 0.002) and VT/VF requiring ICD therapy (HR = 1.50; P = 0.02). Conclusions: Patients in MADIT II who were predominantly paced had a higher rate of new or worsened heart failure and were more likely to receive therapy for VT/VF. These results suggest the deleterious consequences of RV pacing, particularly in the setting of severe LV dysfunction.
Sex Differences in VT/VF or Death in MADIT‐CRT Introduction Studies suggest that women with ischemic heart disease are less likely to experience appropriate ICD therapies for ventricular arrhythmias (VT/VF). We evaluated the influence of sex on arrhythmic events or death in subjects enrolled in MADIT‐CRT. Methods and Results Arrhythmic event rates, defined as VT/VF treated with defibrillator therapy or all‐cause death, were determined among 1,790 subjects enrolled in MADIT‐CRT with documented 3‐year follow‐up. Predictors of VT/VF/death were identified using multivariate analysis. Ninety‐one (21%) women and 466 (35%) men experienced VT/VF/death over the follow‐up period. The overall probability of VT/VF/death was significantly lower in women versus men (HR 0.62; P < 0.001). The probability of VT/VF/death was the lowest in women with ischemic heart disease (HR 0.51; P = 0.003). In ICD subjects, the 3‐year risk of VT/VF was lower in ischemic women versus men (P = 0.021), and in nonischemic women versus men (P = 0.049). The probability of VT/VF/death was significantly lower in women (HR 0.52; P = 0.007) and men (HR 0.74; P = 0.018) with LBBB who received CRT‐D. Appropriate shock therapy strongly correlated with increased risk of death during postshock follow‐up in women (HR 5.18; P = 0.001) and men (HR 1.63; P = 0.033); interaction P value of 0.034. Conclusion In this substudy of MADIT‐CRT, sex, etiology of heart disease and type of device implanted significantly influenced subsequent risk for VT/VF or death. Women with ischemic heart disease and women with LBBB who received CRT‐D had the lowest incidence of VT/VF or death when compared to men. Appropriate shock therapy was a strong predictor of death, particularly in women.