Abstract Hemorrhage is the second leading cause of death in patients under 46 years of age in the United States. Cessation of hemorrhage prevents hemorrhagic shock and tissue hypoxia. Controlling the bleed via direct pressure or tourniquet is often the first line of defense, but long‐term care requires staples, hemostatic agents, or sealants that seal the vessel and restore blood flow. Here, we compare a new photocurable extracellular matrix sealant (pcECM) with low, medium, and high crosslink density formulations to a commercially available fibrin‐based sealant, TISSEEL®. pcECM has potential uses in surgical and remote settings due to room temperature storage conditions and fast preparation time. Here, we determine if pcECM sealant can stop venous hemorrhage in a murine model, adhere to the wound site in vivo throughout the wound‐healing process, and has the mechanical properties necessary for stopping hemorrhage. Adjusting pcECM crosslinking density significantly affected viscosity, swelling, burst strength, tensile strength, and elasticity of the sealant. 3‐Dimensional ultrasound volume segmentations showed pcECM degrades to 17 ± 8% of its initial implant volume by day 28. Initially, local hemodynamic changes were observed, but returned close to baseline levels by day 28. Acute inflammation was observed near the puncture site in pcECM implanted mice, and we observed inflammatory markers at the 14‐day explant for both sealants. pcECM and fibrin sealant successfully sealed the vessel in all cases, and consistently degraded over 14–28 days. pcECM is a durable sealant with tunable mechanical properties and possible uses in hemorrhage control and other surgical procedures.
ABSTRACT Environmental mechanical cues are critical to guide cell fate. Forces transmit to the nucleus through the Linker of Nucleo- and Cytoskeleton (LINC) complex and are thought to influence the organization of chromatin that is related to cell differentiation; however, the underlying mechanisms are unclear. Here, we investigated chromatin reorganization during murine cardiac development and found that cardiomyocytes establish a distinct architecture characterized by relocation of H3K9me3-modified chromatin from the nuclear interior to the periphery and co-localization to myofibrils. This effect was abrogated in stiff environments that inhibited cardiomyocyte contractility, or after LINC complex disruption, and resulted in the relocation of H3K27me3-modified chromatin instead. By generating high-resolution intra-nuclear strain maps during cardiomyocyte contraction, we discovered that the reorganization of H3K9me3-marked chromatin is influenced by tensile, but not compressive, nuclear strains. Our findings highlight a new role for nuclear mechanosensation in guiding cell fate through chromatin reorganization in response to environmental cues.
Recent applications of computational fluid dynamics (CFD) applied to the cardiovascular system have demonstrated its power in investigating the impact of hemodynamics on disease initiation, progression, and treatment outcomes. Flow metrics such as pressure distributions, wall shear stresses (WSS), and blood velocity profiles can be quantified to provide insight into observed pathologies, assist with surgical planning, or even predict disease progression. While numerous studies have performed simulations on clinical human patient data, it often lacks prediagnosis information and can be subject to large intersubject variability, limiting the generalizability of findings. Thus, animal models are often used to identify and manipulate specific factors contributing to vascular disease because they provide a more controlled environment. In this review, we explore the use of CFD in animal models in recent studies to investigate the initiating mechanisms, progression, and intervention effects of various vascular diseases. The first section provides a brief overview of the CFD theory and tools that are commonly used to study blood flow. The following sections are separated by anatomical region, with the abdominal, thoracic, and cerebral areas specifically highlighted. We discuss the associated benefits and obstacles to performing CFD modeling in each location. Finally, we highlight animal CFD studies focusing on common surgical treatments, including arteriovenous fistulas (AVF) and pulmonary artery grafts. The studies included in this review demonstrate the value of combining CFD with animal imaging and should encourage further research to optimize and expand upon these techniques for the study of vascular disease.
An abdominal aortic aneurysm (AAA), defined as a pathological expansion of the largest artery in the abdomen, is a common vascular disease that frequently leads to death if rupture occurs. Once diagnosed, clinicians typically evaluate the rupture risk based on maximum diameter of the aneurysm, a limited metric that is not accurate for all patients. In this study, we worked to evaluate additional distinguishing factors between growing and stable murine aneurysms toward the aim of eventually improving clinical rupture risk assessment. With the use of a relatively new mouse model that combines surgical application of topical elastase to cause initial aortic expansion and a lysyl oxidase inhibitor, β-aminopropionitrile (BAPN), in the drinking water, we were able to create large AAAs that expanded over 28 days. We further sought to develop and demonstrate applications of advanced imaging approaches, including four-dimensional ultrasound (4DUS), to evaluate alternative geometric and biomechanical parameters between 1) growing AAAs, 2) stable AAAs, and 3) nonaneurysmal control mice. Our study confirmed the reproducibility of this murine model and found reduced circumferential strain values, greater tortuosity, and increased elastin degradation in mice with aneurysms. We also found that expanding murine AAAs had increased peak wall stress and surface area per length compared with stable aneurysms. The results from this work provide clear growth patterns associated with BAPN-elastase murine aneurysms and demonstrate the capabilities of high-frequency ultrasound. These data could help lay the groundwork for improving insight into clinical prediction of AAA expansion.NEW & NOTEWORTHY This work characterizes a relatively new murine model of abdominal aortic aneurysms (AAAs) by quantifying vascular strain, stress, and geometry. Furthermore, Green-Lagrange strain was calculated with a novel mapping approach using four-dimensional ultrasound. We also compared growing and stable AAAs, finding peak wall stress and surface area per length to be most indicative of growth. In all AAAs, strain and elastin health declined, whereas tortuosity increased.
Prevention of fracture through improved bone mechanical strength is of great importance given the large number of bone disease-related fractures each year, the decreased quality of life associated with fractures, and the large anticipated increase in fracture incidence over the upcoming years due to the aging population. Exercise and other forms of mechanical stimulation have been shown to increase bone mass, suggesting improved strength. However, while bone mass is a good indicator of strength, other components (such as bone quality) also contribute to bone mechanical integrity. While increased bone mass has been explored considerably using both exercise and targeted loading models, the role of mechanical stimulation in altering bone quality has been explored to a lesser degree. Understanding how to improve both the quantity and quality of bone is critical to increasing fracture resistance. Herein, we discuss quantity and quality-based improvements that have been observed using both exercise and targeted loading models of bone adaptation.
Down syndrome (DS), caused by trisomy of human chromosome 21 (Hsa21), is characterized by a spectrum of phenotypes including skeletal abnormalities. The Ts65Dn DS mouse model exhibits similar skeletal phenotypes as humans with DS. DYRK1A, a kinase encoded on Hsa21, has been linked to deficiencies in bone homeostasis in DS mice and individuals with DS. Treatment with Epigallocatechin-3-gallate (EGCG), a known inhibitor of Dyrk1a, improves some skeletal abnormalities associated with DS in mice. EGCG supplements are widely available but the effectiveness of different EGCG-containing supplements has not been well studied.Six commercially available supplements containing EGCG were analyzed, and two of these supplements were compared with pure EGCG for their impact on skeletal deficits in a DS mouse model. The results demonstrate differential effects of commercial supplements on correcting skeletal abnormalities in Ts65Dn mice. Different EGCG-containing supplements display differences in degradation, polyphenol content, and effects on trisomic bone.This work suggests that the dose of EGCG and composition of EGCG-containing supplements may be important in correcting skeletal deficits associated with DS. Careful analyses of these parameters may lead to a better understanding of how to improve skeletal and other deficits that impair individuals with DS.
In vivo imaging has provided a unique framework for studying pathological progression in various mouse models of cardiac disease. Although conventional short-axis motion-mode (SAX MM) ultrasound and cine magnetic resonance imaging (MRI) are two of the most prevalent strategies used for quantifying cardiac function, there are few notable limitations including imprecision, inaccuracy, and geometric assumptions with ultrasound, or large and costly systems with substantial infrastructure requirements with MRI. Here we present an automated 4-dimensional ultrasound (4DUS) technique that provides comparable information to cine MRI through spatiotemporally synced imaging of cardiac motion. Cardiac function metrics derived from SAX MM, cine MRI, and 4DUS data show close agreement between cine MRI and 4DUS but overestimations by SAX MM. The inclusion of a mouse model of cardiac hypertrophy further highlights the precision of 4DUS compared with that of SAX MM, with narrower groupings of cardiac metrics based on health status. Our findings suggest that murine 4DUS can be used as a reliable, accurate, and cost-effective technique for longitudinal studies of cardiac function and disease progression.