Angiosarcomas are primary vascular malignancies with a highly invasive character. The lung is the most common site of metastasis, but primary pulmonary angiosarcomas are rarely reported. We reported a case of suspicious primary pulmonary angiosarcoma with the initial presentation of bilateral lung nodules and pericardial effusion. Diagnosis was made by surgical biopsy via thoracoscopy. The clinical characteristics, histopathologic features and treatment options were also reviewed in this article.
Rapid on-site cytologic evaluation (ROSE) has been shown to improve the diagnostic accuracy of endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB). However, ROSE by a cytopathologist or cytotechnologist is not always available during the procedure. The purposes of this study were to verify that a pulmonologist, after receiving training in cytology, could accurately assess an EBUS-TBB specimen on-site, and to evaluate the contribution of ROSE to EBUS-TBB. A retrospective chart review of patients who underwent EBUS-TBB for diagnosis of peripheral pulmonary lesions (PPLs) from January 2014 to June 2017 was performed. PPLs without a malignant diagnosis were excluded. The ROSE result determined by a pulmonologist was compared to the formal imprint cytologic report and pathologic report. The diagnostic accuracy of EBUS-TBB was also compared between those with and without ROSE. Two hundred ninety-three patients who underwent 336 EBUS-TBB procedures for PPL diagnosis and were found to have proven malignancy were enrolled. Eighty-six procedures were performed with ROSE. With the formal imprint cytologic diagnosis as the standard, ROSE had 96.9% sensitivity, 68.2% specificity, 89.9% positive predictive value (PPV), 88.2% negative predictive value (NPV), and 89.5% diagnostic accuracy. With the formal pathologic result as the standard, ROSE had 88.2% sensitivity, 80% specificity, 97.1% PPV, 47.1% NPV, and 87.2% diagnostic accuracy, respectively. The diagnostic accuracy was significantly higher when ROSE was performed during EBUS-TBB (88.4% vs 68.0%, P < 0.001). A trained pulmonologist can interpret adequately cytologic smears on-site and effectively improve the accuracy of EBUS-TBB in the diagnosis of PPLs.
The aim of this study was to identify easy and relatively effective ultrasound criteria for metastatic mediastinal lymph node prediction.A retrospective chart review of patients who underwent endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) from March 2014 to September 2016 was performed. We used the following EBUS sonographic features for metastatic lymph node prediction: 1) length of the short axis, 2) shape, 3) margin, 4) echogenicity, 5) central hilar structure, and 6) coagulation necrosis sign. These sonographic findings were compared with the final pathology results or clinical follow-up.A total of 227 lymph nodes were retrospectively evaluated in 133 lung cancer patients; 72% of the lymph nodes had been proven to be malignant metastasis. Logistic regression analysis revealed that the length of the short axis, shape, margin, and echogenicity were independent predictive factors for metastasis. We developed a sum score based on these four sonographic features. A larger sum score trended toward a greater possibility of malignancy. If all four predictive factors were preserved, the diagnostic accuracy, the value of the specificity and the positive predictive value of the sonographic feature would be higher than 90%.The sonographic features of EBUS are valuable tools in predicting metastatic lymph nodes in lung cancer patients.
Abstract Background Endobronchial ultrasound (EBUS) and cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) are utilized for the diagnosis of peripheral pulmonary lesions (PPLs). Combining them with transbronchial cryobiopsy (TBC) can provide sufficient tissue for genetic analysis. However, cryoprobes of different sizes have varying degrees of flexibility, which can affect their ability to access the target bronchus and potentially impact the accuracy. The aim of this study was to compare the diagnostic efficacy of cryoprobes of varying sizes in CBCT-AF and EBUS for the diagnosis of PPLs. Methods Patients who underwent endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) and TBC combined with CBCT-AF for PPLs diagnosis between January 2021 and May 2022 were included. Propensity score matching and competing-risks regression were utilized for data analysis. Primary outcome was the diagnostic accuracy of TBC. Results A total of 284 patients underwent TBC, with 172 using a 1.7-mm cryoprobe (1.7 group) and 112 using a 1.1-mm cryoprobe (1.1 group). Finally, we included 99 paired patients following propensity score matching. The diagnostic accuracy of TBC was higher in the 1.1 group (80.8% vs. 69.7%, P = 0.050), with a similar rate of complications. Subgroup analysis also revealed that the 1.1 group had better accuracy when PPLs were located in the upper lobe (85.2% vs. 66.1%, P = 0.020), when PPLs were smaller than 20 mm (78.8% vs. 48.8%, P = 0.008), and when intra-procedural CBCT was needed to be used (79.5% vs. 42.3%, P = 0.001). TBC obtained larger specimens than TBB in both groups. There is still a trend of larger sample size obtained in the 1.7 group, but there is no statistically different between our two study groups (40.8 mm 2 vs. 22.0 mm 2 , P = 0.283). Conclusions The combination of TBC with CBCT-AF and EBUS is effective in diagnosing PPLs, and a thin cryoprobe is preferred when the PPLs located in difficult areas.
Endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) is used for the diagnosis of peripheral pulmonary lesions (PPLs), but the diagnostic yield is not adequate. Cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) can be utilized to assess the location of PPLs and biopsy devices, and has the potential to improve the diagnostic accuracy of bronchoscopic techniques. The purpose of this study was to verify the contribution of CBCT-AF to EBUS-TBB.Patients who underwent EBUS-TBB for diagnosis of PPLs were enrolled. The navigation success rate and diagnostic yield were used to evaluate the effectiveness of CBCT-AF in EBUS-TBB.In this study, 236 patients who underwent EBUS-TBB for PPL diagnosis were enrolled. One hundred fifteen patients were in CBCT-AF group and 121 were in non-AF group. The navigation success rate was significantly higher in the CBCT-AF group (96.5% vs. 86.8%, p = 0.006). The diagnostic yield was even better in the CBCT-AF group when the target lesion was small in size (68.8% vs. 0%, p = 0.026 for lesions ≤10 mm and 77.5% vs. 46.4%, p = 0.016 for lesions 10-20 mm, respectively). The diagnostic yield of the two study groups became similar when the procedures with a failure of navigation were excluded. The procedure-related complication rate was similar between the two study groups.CBCT-AF is safe, and effectively enhances the navigation success rate, thereby increasing the diagnostic yield of EBUS-TBB for PPLs.
Background Microorganisms of tuberculosis (TB) are frequently difficult to identify from the airway specimen; therefore, lung biopsy for further histologic and microbiologic study is required. Endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) is used for the diagnosis of pulmonary malignancy, but is rarely in the TB population. The purpose of this study was to verify the effectiveness and safety of EBUS-TBB with histologic study and tissue culture in the diagnosis of sputum smear-negative pulmonary TB. Methods Patients who underwent EBUS-TBB with histologic study and TB tissue culture for clinically suspected, but sputum smear-negative pulmonary TB from January 2016 to December 2018, were included. The accuracy of each diagnostic modality was calculated, respectively. Factors that might influence the positive rate of TB culture (washing fluid and tissue specimen) were also evaluated. Results One hundred sixty-one patients who underwent EBUS-TBB for clinically suspected, but sputum smear-negative pulmonary TB, were enrolled, and 43 of them were finally diagnosed as having pulmonary TB. The sensitivity of washing fluid (a combination of smear, culture, and polymerase chain reaction for TB) and tissue specimen (a combination of pathology and tissue culture) via EBUS-TBB for TB diagnosis were 48.8 and 55.8%, respectively. The sensitivity for TB diagnosis would be elevated to 67.4% when both washing fluid and tissue specimens are used. The positive TB culture rate would not statistically increase with a combination of tissue specimens and washing fluid. Univariate analysis revealed that TB microorganisms would be more easily cultivated when lesions had an abscess or cavity on the computed tomography (CT) image (presence vs. absence; 62.5 vs. 26.3%, p = 0.022), heterogeneous echogenicity on the EBUS finding (heterogeneous vs. homogeneous; 93.3 vs. 21.4%, p = 0.001), or a necrotic pattern via histologic study (presence vs. absence; 70.6 vs. 30.8%, p = 0.013). Heterogeneous echogenicity in the EBUS finding was the independent predictor according to the results of multivariate analysis. None of our patients encountered major adverse events or received further intensive care after EBUS-TBB. Conclusion Endobronchial ultrasound-guided transbronchial biopsy is safe and effective for use in diagnosing sputum smear-negative pulmonary TB. EBUS echoic feature is also a predictor of the positive TB culture rate in pulmonary TB. However, tissue culture via EBUS-TBB has little effect in improving the positive TB culture rate.
Abstract Background Endobronchial ultrasound (EBUS) and cone-beam computed tomography-derived augmented fluoroscopy (CBCT-AF) are utilized for the diagnosis of peripheral pulmonary lesions (PPLs). Combining them with transbronchial cryobiopsy (TBC) can provide sufficient tissue for genetic analysis. However, cryoprobes of different sizes have varying degrees of flexibility, which can affect their ability to access the target bronchus and potentially impact the accuracy. The aim of this study was to compare the diagnostic efficacy of cryoprobes of varying sizes in CBCT-AF and EBUS for the diagnosis of PPLs. Methods Patients who underwent endobronchial ultrasound-guided transbronchial biopsy (EBUS-TBB) and TBC combined with CBCT-AF for PPLs diagnosis between January 2021 and May 2022 were included. Propensity score matching and competing-risks regression were utilized for data analysis. Results A total of 284 patients underwent TBC, with 172 using a 1.7-mm cryoprobe (1.7 group) and 112 using a 1.1-mm cryoprobe (1.1 group). Finally, we included 99 paired patients following propensity score matching. The diagnostic accuracy of TBC was higher in the 1.1 group (80.8% vs 69.7%, P = 0.050), with a similar rate of complications. Subgroup analysis also revealed that the 1.1 group had better accuracy when PPLs were located in the upper lobe (85.2% vs 66.1%, P = 0.020) and when PPLs were smaller than 20 mm (78.8% vs 48.8%, P = 0.008). TBC obtained larger specimens than TBB in both groups. The sample size obtained by TBC did not differ between the 1.7 and 1.1 groups (40.8 mm 2 vs 22.0 mm 2 , P = 0.283). Conclusions The combination of TBC with CBCT-AF and EBUS is effective and safe in diagnosing PPLs, and a thin cryoprobe is preferred when the PPLs located in difficult areas.
Endobronchial ultrasound (EBUS) elastography is a new technique that provides information on tissue compressibility during endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA). The purposes of this study were to evaluate the utility of EBUS elastography in differentiating malignant and benign mediastinal lymph nodes (LNs) and to explore the factors that influence its accuracy. A retrospective chart review of patients who underwent EBUS-TBNA from October 2016 to July 2017 was performed. EBUS with conventional B-mode features and elastographic patterns were compared with the final pathology results or clinical follow-up. We used the following EBUS elastographic patterns for classification: type 1, predominantly non-blue (green, yellow and red); type 2, part blue, part non-blue; type 3, predominantly blue. The potential impacts of the characteristics of LNs, the underlying lung diseases and obtaining fibrotic components from EBUS-TBNA specimens were evaluated relative to the accuracy of EBUS elastography. A total of 206 LNs from 94 patients were retrospectively evaluated. In classifying type 1 as ‘benign’ and type 3 as ‘malignant,’ the sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy rate were 90.6, 82.6, 71.6, 94.7 and 85.2%, respectively. The EBUS elastographic patterns had higher diagnostic yields and negative predictive values than conventional B-mode features. Logistic regression analysis revealed that central necrosis was a factor that influenced the accuracy of elastography in malignant LNs. The fibrotic component within benign LNs could cause an incorrect elastographic pattern. EBUS elastography is a valuable tool in discriminating benign and malignant mediastinal LNs.