Background Standard surgical treatments for lower urinary tract symptoms (LUTS) due to benign prostatic obstruction (BPO) use a transurethral approach. Drawbacks are the need for general or spinal anesthesia and complications such as hematuria, strictures, and cloth retention. Therefore, a minimal invasive technique under local anesthesia is desired to improve patient safety. Recently, SoracteLite transperineal laser ablation (TPLA) has been introduced as a novel minimal invasive treatment for BPO. The system used is unique because 4 laser sources are independently available. This 1064-nm diode laser induces coagulative necrosis. Moreover, TPLA is unique because it has a transperineal approach and can be performed under local anesthesia in an outpatient setting. Objective The primary objective of this study is to determine the safety and feasibility of TPLA treatment for men, who are fit for standard surgery, with LUTS due to BPO. The secondary objectives are to determine functional outcomes by flowmetry and patient-reported outcome measures (PROMs), side effects, and tissue changes observed on imaging. Methods This study is a prospective, single center, interventional pilot study IDEAL framework stage 2a and will include 20 patients. Eligible patients are men ≥40 years of age, with a prostate volume of 30 to 120 cc, have urodynamically proven bladder outlet obstruction, and have a peak urinary flow of 5 to 15 mL per second. All patients will undergo TPLA of their prostate under local anesthesia by using the EchoLaser system. Depending on the prostate volume, 2 to 4 laser fibers will be placed bilaterally into the prostate. Patient follow-up consists of uroflowmetry, PROMs, and imaging by using contrast-enhanced ultrasound. Total follow-up is 12 months following treatment. Results Presently, recruitment of patients is ongoing. Publication of first results is expected by early 2020. Conclusions TPLA offers the potential to be a novel minimal invasive technique for treatment of LUTS due to BPO in men fit for standard desobstruction. This study will evaluate the safety and feasibility of TPLA and report on functional outcomes and tissue changes observed on imaging following TPLA treatment. International Registered Report Identifier (IRRID) DERR1-10.2196/15687
Intraoperative indocyanine green fluorescence angiography (ICG-FA) may be of added value during pouch surgery, in particular after vascular ligations as lengthening maneuver. The aim was to determine quantitative perfusion parameters within the efferent/afferent loop and explore the impact of vascular ligation. Perfusion parameters were also compared in patients with and without anastomotic leakage (AL).All consenting patients that underwent FA-guided ileal pouch-anal anastomosis (IPAA) between July 2020 and December 2021 were included. After intravenous bolus injection of 0.1 mg/kg ICG, the near-infrared camera (Stryker Aim 1688) registered the fluorescence intensity over time. Quantitative analysis of ICG-FA from standardized regions of interests on the pouch was performed using software. Fluorescence parameters were extracted for inflow (T0, Tmax, Fmax, slope, Time-to-peak) and outflow (T90% and T80%). Change of management related to FA findings and AL rates were recorded.Twenty-one patients were included, three patients (14%) required vascular ligation to obtain additional length, by ligating terminal ileal branches in two and the ileocolic artery (ICA) in one patient. In nine patients the ICA was already ligated during subtotal colectomy. ICG-FA triggered a change of management in 19% of patients (n = 4/21), all of them had impaired vascular supply (ligated ileocolic/ terminal ileal branches). Overall, patients with intact vascular supply had similar perfusion patterns for the afferent and efferent loop. Pouches with ICA ligation had longer Tmax in both afferent as efferent loop than pouches with intact ICA (afferent 51 and efferent 53 versus 41 and 43 s respectively). Mean slope of the efferent loop diminished in ICA ligated patients 1.5(IQR 0.8-4.4) versus 2.2 (1.3-3.6) in ICA intact patients.Quantitative analysis of ICG-FA perfusion during IPAA is feasible and reflects the ligation of the supplying vessels.
BACKGROUND Needle-free hyaluronic acid (HA) jet injectors are gaining popularity for rejuvenation treatment. The devices are widely available online and are used for self-injection or in beauty salons by nonphysicians. However, little is known about their performance and safety. OBJECTIVE To explore the injection efficiency and cutaneous biodistribution patterns administered with home-use compared with medical jet injectors and to assess safety aspects. MATERIALS AND METHODS The authors injected HA into ex vivo human skin with 4 home-use and 2 medical injectors. The intracutaneous dose of HA was calculated, and the cutaneous biodistribution of HA was assessed using a 3-dimensional Fluorescent Imaging Cryomicrotome System (3D-FICS). Safety aspects were evaluated based on the presence of a manual, CE (conformité européenne) mark, and sterility. RESULTS The intracutaneous dose delivered by the home-use injectors was markedly lower compared with the medical injectors. 3D imaging for home-use injectors showed superficial epidermal distribution with low distribution volumes. For medical injectors, volumes were substantially larger and mainly middermal. All evaluated safety aspects were lacking. CONCLUSION Results of this study suggest that the specific combinations of home-use injectors and HA used in this study are unreliable and unsafe, which casts doubts on the performance of these treatments in general.
Despite the improvements in early cancer diagnosis, adequate diagnostic tools for early staging of bladder cancer tumors are lacking [1]. MEMS-probes based on optical coherence tomography (OCT) provide cross-sectional imaging with a high-spatial resolution at a high-imaging speed, improving visualization of cancerous tissue [2-3]. Additionally, studies show that the measurement of localized attenuation coefficient allows discrimination between healthy and cancerous tissue [4]. We have designed a new miniaturized MEMS-probe based on OCT that will optimize early diagnosis by improving functional visualization of suspicious lesions in bladder. During the optical design phase of the probe, we have studied the effect of the numerical aperture (NA) on the OCT signal attenuation. For this study, we have employed an InnerVision Santec OCT system with several numerical apertures (25mm, 40mm, 60mm, 100mm, 150mm and 200mm using achromatic lenses). The change in attenuation coefficient was studied using 15 dilutions of intralipid ranging between 6*10-5 volume% and 20 volume%. We obtained the attenuation coefficient from the OCT images at several fixed positions of the focuses using established OCT models (e.g. single scattering with known confocal point spread function (PSF) [5] and multiple scattering using the Extended Huygens Fresnel model [6]). As a result, a non-linear increase of the scattering coefficient as a function of intralipid concentration (due to dependent scattering) was obtained for all numerical apertures. For all intralipid samples, the measured attenuation coefficient decreased with a decrease in NA. Our results suggest a non-negligible influence of the NA on the measured attenuation coefficient. [1] Khochikar MV. Rationale for an early detection program for bladder cancer. Indian J Urol 2011 Apr-Jun; 27(2): 218–225. [2] Sun J and Xie H. Review Article MEMS-Based Endoscopic Optical Coherence Tomography. IJO 2011, Article ID 825629, 12 pages. doi:10.1155/2011/825629. [3] Jung W and Boppart S. Optical coherence tomography for rapid tissue screening and directed histological sectioning. Anal Cell Pathol (Amst). 2012; 35(3): 129–143. [4] R. Wessels et al. Optical coherence tomography in vulvar intraepithelial neoplasia. J Biomed Opt 2012 Nov; 17(11): 116022. [5] Faber D, van der Meer F, Aalders M, van Leeuwen T. Quantitative measurement of attenuation coefficients of weakly scattering media using optical coherence tomography. OPT EXPRESS 2004; 12 (19): 4353-43. [6] Thrane L, Yura HT, and Andersen PE. Analysis of optical coherence tomography systems based on the extended Huygens–Fresnel principle. JOSA 2000; 17(3): 484-490.
Near infrared imaging (NIR) camera systems have been clinically deployed to visualize intravenous injected indocyanine green (ICG) spreading through the vascular bed, thereby creating the ability to assess tissue perfusion. While standardization is key to make fluorescence angiography (FA) comparable and reproducible, optical characteristics like field illumination homogeneity are often not considered. Therefore the aim of this study is to investigate light distribution and the center-periphery effect among five different NIR imaging devices in an indocyanine green phantom. A 13 × 13 cm fluorescence phantom was created by diluting ICG in Intralipid (representing 0.1 mg/kg dose in an 80 kg reference male), to evaluate the overall spatial collection efficiency with fluorescent modalities of five different NIR camera systems using a 0-degree laparoscope. The fluorescence signal from the phantom was quantified at a fixed distance of 16 cm using tailor-made software in Python. The results showed considerable variability in regard to light distribution among the five camera systems, especially toward the periphery of the field of view. In conclusion, NIR signal distribution varies between different systems and within the same displayed image. The fluorescence intensity diminishes peripherally away from the center of the field of view. These optical phenomena need to be considered when clinically interpreting the signal and in the development of computational fluorescence quantification.
Compromised perfusion due to ligation of arteries and veins in esophagectomy with gastric tube reconstruction often (5–20%) results in necrosis and anastomotic leakage, which relate to high morbidity and mortality (3–4%). Ephedrine is used widely in anesthesia to treat intraoperative hypotension and may improve perfusion by the increase of cardiac output and mean arterial pressure (MAP). This study tests the effect of ephedrine on perfusion of the future anastomotic site of the gastric conduit, measured by laser speckle contrast imaging (LSCI). This prospective, observational, in vivo pilot study includes 26 patients undergoing esophagectomy with gastric tube reconstruction from October 2015 to June 2016 in the Academic Medical Center (Amsterdam). Perfusion of the gastric conduit was measured with LSCI directly after reconstruction and after an increase of MAP by ephedrine 5 mg. Perfusion was quantified in flux (laser speckle perfusion units, LSPU) in four perfusion locations, from good perfusion (base of the gastric tube) toward decreased perfusion (fundus). Intrapatient differences before and after ephedrine in terms flux were statistically tested for significance with a paired t-test. LSCI was feasible to image gastric microcirculation in all patients. Flux (LSPU) was significantly higher in the base of the gastric tube (791 ± 442) compared to the fundus (328 ± 187) (P < 0.001). After administration of ephedrine, flux increased significantly in the fundus (P < 0.05) measured intrapatients. Three patients developed anastomotic leakage. In these patients, the difference between measured flux in the fundus compared to the base of the gastric tube was high. This study presents the effect of ephedrine on perfusion of the gastric tissue measured with LSCI in terms of flux (LSPU) after esophagectomy with gastric tube reconstruction. We show a small but significant difference between flux measured before and after administration of ephedrine in the future anastomotic tissue (313 ± 178 vs. 397 ± 290). We also show a significant decrease of flux toward the fundus.