The recognition of the correct pattern and severity of deformity in knee osteoarthritis has important implications in its surgical management. Our unit routinely uses standing long leg films and computer navigation. However, these modalities are not widely available and most surgeons rely on clinical assessment and short films. Our experience is that clinical assessment can give the opposite impression of the true deformity pattern particularly among obese patients and there is evidence that short knee films are not reliable. Our study aims to compare clinical, radiographic and computer measurements of knee deformity, assess the influence of Body Mass Index and asses the relationship between coronal and flexion deformity.
We measured 52 consecutive knees prior to arthroplasty using clinical, long leg radiographs and computer navigation methods. Systematic clinical measurement was done with patient standing. Standing radiographs stored in a Picture Archiving System were measured by two independent observers. The senior surgeon performed computer measurement while applying axial load to the foot to simulate weight bearing.
Using long leg films as baseline, clinical and X-ray measurement had a mean error of 0.8° (−12 to +12). Seven clinically valgus knees turned out varus on X-ray. Mean BMI for this group was the same as the rest. Using navigation as baseline, clinical and navigation coronal measurements had a mean error of 0.3° (+9 to −10.5). Four clinically valgus knees turned out varus with navigation. Mean BMI for this group was the same as the rest. Flexion deformity was similar between clinical and computer measurement. Three clinically normal knees showed significant varus in both X-ray and navigation. Compared directly, radiographic and navigation coronal deformity showed significant difference in the degree of deformity but not in the pattern of deformity. There was no correlation between BMI and both the error in clinical assessment of coronal deformity and navigation coronal alignment. If flexion deformity was >5°, higher BMI indicates higher flexion deformity. There was a weak correlation between navigation coronal and flexion deformity.
Although error in clinical measurement did not reach statistical significance, based on our result, clinical assessment can give an incorrect pattern of deformity in up to 13% and hence should not be the sole basis of assessing deformity. Contrary to expectation, BMI did not influence error of clinical assessment or severity of coronal deformity. It however appeared to influence larger flexion deformities. The discrepancy between radiographic and navigation measurements reflects the absence of true weight bearing with navigation even though we tried to simulate this by applying axial load to the foot.
Tranexamic Acid (TA) has been shown to reduce transfusion rates in Total Knee Replacement (TKR) without complication. In our unit it was added to our routine enhanced recovery protocol. No other changes were made to the protocol at this time and as such we sought to examine the effects of TA on wound complication and transfusion rate.All patients undergoing primary TKR over a 12 month period were identified. Notes and online records were reviewed to collate demographics, length of stay, use of TA, thromboprophylaxis, blood transfusion, wound complications and haemoglobin levels. All patients received a Columbus navigated TKR with a tourniquet. Only patients who received 14 days of Dalteparin for thromboprophylaxis were included.124 patients were included, 72 receiving TA and 52 not. Mean age was 70. Four patients required a blood transfusion all of whom did not receive TA (p = 0.029). Mean change in Hb was 22 without TA and 21 with (p = 0.859). Mean length of stay was 6.83 days without Tranexamic Acid and...
Rivaroxaban has been recommended for routine use as a thromboprophylactic agent in patients undergoing lower-limb arthroplasty. Starting January 2011, our unit has converted from aspirin to Rivaroxaban use routinely following lower-limb arthroplasty for venous thromboembolism (VTE) prophylaxis. The aim of this audit was to retrospectively review its efficacy and the morbidity associated with its use.All patients undergoing primary and revision lower-limb arthroplasty between February 2011 and July 2011 were reviewed. All patients undergoing total knee replacement surgery and total hip replacement surgery received oral rivaroxaban 10 mg daily post-operatively for 14 days and 35 days respectively. Outcome measures recorded were; investigation for DVT/PE, rate of DVT/PE, wound complications (infection, dehiscence, leaking, bleeding), blood transfusion rate and readmission rate within 6 weeks of surgery.Of the 162 patients identified, 19 were excluded due to insufficient information or because they did not re...
In this study we assess the clinical and radiological outcomes after surgical fixation of unstable, extracapsular fractures of the proximal femur using two designs of short intramedullary nail. We reviewed 158 patients of which 131 had fixation using the Intra Medullary Hip Screw (IMHS original Richards Compression Hip Screw design) and 27 with the original design Proximal Femoral Nail (PFN Synthes). Outcome measures including non-union, peri-implant fracture, post-operative function and mortality were similar between groups. Proximal screw cut-out and consequently re-operation rate were significantly higher for the PFN. A number of variables may predispose a patient to develop screw cut-out including gender, experience of surgeon, fracture pattern, implant design and tip-apex distance. As such a multivariable logistic regression model was used to investigate the independent effects of these variables on proximal screw cut-out. Only tip-apex distance was found to have a significant association with proximal screw cut-out and differences between implant designs could be accounted for by surgical technique rather than implant design. The results of this study suggest that both implants have similar post-operative outcome measures and complication rates when implanted correctly.
Objective: Despite advances in treatment, the management of fracture non-union remains a challenging and complex problem in orthopaedics. Low-intensity pulsed ultrasound (LIPUS) treatment has been shown to be an effective, non-invasive, affordable treatment option. This treatment was evaluated in a Scottish district hospital over a nine-year period, which included the COVID-19 pandemic. Materials and methods: This submission describes a case series at Dr Gray’s Hospital in Scotland, 18 patients in whom fracture non-union was treated using LIPUS. Results: An overall healing rate of 94% was achieved. Exogen™ (Bioventus LLC, NC, USA) proved to be most successful in oligotrophic non-union. No observed patient demographic appeared predictive of outcome. LIPUS treatment failed in one case. No significant adverse effects of LIPUS were detected. Conclusion: LIPUS represents a useful, cost-effective potential alternative to revision surgery. LIPUS may therefore be the preferred treatment when surgical intervention and face-to-face interactions are to be minimised, as during the COVID-19 pandemic.
Sustaining an intracapsular fracture in a hip which was previously fixed with dynamic hip screw for extracapsular fracture, is a very rarely reported occurrence. We present one such case in order to discuss the presentation and management of this fracture. We have also reviewed the literature and pooled the previously reported cases to look at potential cause & risk factors.