There is a growing interest in Gafchromic® films for patient dosimetry in radiotherapy and in radiology. A new model (XR-QA) with high sensitivity to low dose was tested in this study. The response of the film to different x-ray beam energies (range 28–145 kVp with various filtrations, dose range 0–100 mGy) and to visible light was investigated, together with the after exposure darkening properties. Exposed films were digitized with a commercially available, optical flatbed scanner. A single functional form for dose versus net pixel value variation has been determined for all the obtained calibration curves, with a unique fit parameter different for each of the used x-ray beams. The film response was dependent on beam energy, with higher colour variations for the beams in the range 80–140 kVp. Different sources of uncertainties in dose measurements, governed by the digitalization process, the film response uniformity and the calibration curve fit procedure, have been considered. The overall one-sigma dose measurement uncertainty depended on the beam energy and decreased with increasing absorbed dose. For doses above 10 mGy and beam energies in the range 80–140 kVp the total uncertainty was less than 5%, whereas for the 28 kVp beam the total uncertainty at 10 mGy was about 10%. The post-exposure colour variation was not negligible in the first 24 h after the exposure, with a consequent increase in the calculated dose of about 10%. Results of the analysis of the sensitivity to visible light indicated that a short exposure of this film to ambient and scanner light during the measurements will not have a significant impact on the radiation dosimetry.
Interventional neuroradiology can involve very high entrance skin doses to patients and has the potential to induce deterministic radiation effects to the skin. A monitoring system indicating the maximum entrance skin dose during procedures could be useful to avoid skin injuries and to optimize technical parameters. Such evaluation is difficult, because exposure conditions change many times during each procedure. A data acquisition system for real time estimation of patient dose was developed, using a transmission ionization chamber connected to a personal computer, simultaneously measuring air kerma and dose area product. Input data were processed by a software that provided a map of entrance skin dose and stored all the information in a database. The method was first applied during 16 interventional procedures and was found to be suitable to this application thanks to the short time necessary for dose measurements, simplicity of use and absence of interference with the procedure execution. The uncertainty of estimation of maximum entrance skin dose was evaluated to be about 20% at the 1 sigma level.
Poster: ECR 2017 / C-1644 / ASIR and ASIR-V iterative reconstruction comparison: low contrast detectability, noise and dose evaluations with an anthropomorphic phantom by: O. Rampado1, F. Marchisio2, M. Gatti1, P. isoardi1, R. ropolo1, G. Gandini1; 1Turin/IT, 2Torino, TO/IT
(1.1) to evaluate the association between baseline 18F-FDG PET/CT semi-quantitative parameters of the primary lesion with progression free survival (PFS), overall survival (OS) and response to immunotherapy, in advanced non-small cell lung carcinoma (NSCLC) patients eligible for immunotherapy; (1.2) to evaluate the application of radiomics analysis of the primary lesion to identify features predictive of response to immunotherapy; (1.3) to evaluate if tumor burden assessed by 18F-FDG PET/CT (N and M factors) is associated with PFS and OS.we retrospectively analyzed clinical records of advanced NCSLC patients (stage IIIb/c or stage IV) candidate to immunotherapy who performed 18F-FDG PET/CT before treatment to stage the disease. Fifty-seven (57) patients were included in the analysis (F:M 17:40; median age = 69 years old). Notably, 38/57 of patients had adenocarcinoma (AC), 10/57 squamous cell carcinoma (SCC) and 9/57 were not otherwise specified (NOS). Overall, 47.4% patients were stage IVA, 42.1% IVB and 8.8% IIIB. Immunotherapy was performed as front-line therapy in 42/57 patients and as second line therapy after chemotherapy platinum-based in 15/57. The median follow up after starting immunotherapy was 10 months (range: 1.5-68.6). Therapy response was assessed by RECIST 1.1 criteria (CT evaluation every 4 cycles of therapy) in 48/57 patients or when not feasible by clinical and laboratory data (fast disease progression or worsening of patient clinical condition in nine patients). Radiomics analysis was performed by applying regions of interest (ROIs) of the primary tumor delineated manually by two operators and semi-automatically applying a threshold at 40% of SUVmax.(1.1) metabolic tumor volume (MTV) (p = 0.028) and total lesion glycolysis (TLG) (p = 0.035) were significantly associated with progressive vs. non-progressive disease status. Patients with higher values of MTV and TLG had higher probability of disease progression, compared to those patients presenting with lower values. SUVmax did not show correlation with PD status, PFS and OS. MTV (p = 0.027) and TLG (p = 0.022) also resulted in being significantly different among PR, SD and PD groups, while SUVmax was confirmed to not be associated with response to therapy (p = 0.427). (1.2) We observed the association of several radiomics features with PD status. Namely, patients with high tumor volume, TLG and heterogeneity expressed by "skewness" and "kurtosis" had a higher probability of failing immunotherapy. (1.3) M status at 18F-FDG PET/CT was significantly associated with PFS (p = 0.002) and OS (p = 0.049). No significant associations were observed for N status.18F-FDG PET/CT performed before the start of immunotherapy might be an important prognostic tool able to predict the disease progression and response to immunotherapy in patients with advanced NSCLC, since MTV, TLG and radiomics features (volume and heterogeneity) are associated with disease progression.
Quality control of cone-beam computed tomography (CBCT) systems is an essential part of quality assurance to periodically check that quality requirements are met, reduce uncertainties and errors an ...