The novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) pandemic has rapidly spread across the globe. The clinical spectrum of infection with SARS-CoV-2 among the most vulnerable extremely premature patient population in the neonatal intensive care units (NICUs), particularly those with chronic lung disease (CLD), remains unclear. Additionally, post-COVID conditions have been described in children with limited published data among infants. Symptoms in children appear similar to those described in the adults. We report a case of SARS-CoV-2 infection in a 24-week preterm infant with CLD acquired via horizontal transmission while still in the NICU. We also provide follow-up data on patient until one year post-discharge. Our patient developed fever prompting testing for SARS-CoV-2. Although extremely premature infants with CLD are known to be at high risk for morbidities if they acquire respiratory viral infections, infection with SARS-CoV-2 in this case report presented with relatively mild clinical symptoms. He remained clinically stable on respiratory support (nasal cannula) with eventual weaning to room air. Our patient was followed until one year post-discharge (chronological age: 20 months) and had follow-up by various subspecialties for chronic lung disease, hypothyroidism, chronic kidney disease, and poor growth. We did not observe any specific post-COVID symptoms. This case illustrates that horizontal transmission of SARS-CoV-2 infection among extremely premature infants with CLD is possible in the NICU but likely presents with mild clinical symptoms during acute infection and less chances of post-COVID conditions. Additionally, this case highlights the need for adherence to infection prevention guidelines to prevent nosocomial transmission amid the ongoing pandemic.
A diagnosis of intra-amniotic infection is typically made based on clinical criteria, including maternal intrapartum fever and one or more of the following: maternal leukocytosis, purulent cervical drainage, or fetal tachycardia. The diagnosis can also be made in patients with an isolated fever of 39°C, or greater, without any other clinical risk factors present. Coronavirus disease 2019 (COVID-19), caused by the virus SARS-CoV-2, has been noted to have varying signs and symptoms over the course of the disease including fever, cough, fatigue, anorexia, shortness of breath, sputum production, and myalgia. In this report, we detail a case of a newborn born to a mother with a clinical diagnosis of intra-amniotic infection with maternal fever and fetal tachycardia, who was then found to be SARS-CoV-2 positive on testing. Due to the varying presentation of COVID-19, this case illustrates the low threshold needed to test mothers for SARS-CoV-2 in order to prevent horizontal transmission to neonates and to healthcare providers.
A 64-year-old man underwent phacoemulsification surgery in left eye for senile cataract with nuclear sclerosis grade 4 using Standard 20 gauge aspiration bypass system (ABS) phacoemulsification tip (Centurion, Alcon laboratories, Inc., Fort Worth, TX, USA). During phacoemulsification, sudden fracture of the flared titanium tip was noted while attempting chopping [Fig. 1a]. The broken end was removed while still inside the silicon sleeve [Fig. 1b]. There was no damage to ocular tissues. Anterior chamber was examined thoroughly under operating microscope and no broken piece was seen. This was confirmed by opposing the broken ends of the tip under the microscope, which matched perfectly without any broken piece. Surgery was completed using a new tip without further complications.Figure 1: (a) Smooth break in phacoemulsification tip during chopping manoeuvre. (b) Removal of broken phacoemulsification tip inside sleeve using second instrumentOn electron microscopy, the phacoemulsification tip showed a smooth break in both the ends with crack around the ABS microhole [Fig. 2a and b]. The ABS microhole may have been the site of weakness leading to cracking and fracture of phaco tip.Figure 2: Electron microscopy of broken ends of phacoemulsification tip. (a) Smooth crack noted in both ends of broken tip. (b) Crack around ABS microhole in magnified view (10×)Discussion Breaking of instruments intraoperatively during phacoemulsification may cause damage to intraocular tissue.[123] In most cases, break is noted in the second instrument, such as chopper, sinskey hook, or spatula, which may have come in contact with phacoemulsification tip.[34] In rare cases, break may be noted in phacoemulsification tip.[5] Early detection and removal of broken phacoemulsification tip inside its sleeve helps in avoiding inadvertent damage. Declaration of patient consent The authors certify that they have obtained all appropriate patient consent forms. In the form the patient(s) has/have given his/her/their consent for his/her/their images and other clinical information to be reported in the journal. The patients understand that their names and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
Congenital diaphragmatic hernia (CDH) in neonates may occur as an isolated finding, in association with other anomalies, or as part of a genetic syndrome. We report the first case of an infant with CDH who presented with hyponatremic seizures due to adrenal hypoplasia congenita (AHC). The patient underwent repair of CDH defect. After an uncomplicated postoperative course while on discharge planning, he developed a seizure episode associated with severe hyponatremia and hyperkalemia. Extensive diagnostic workup revealed an NR0B1 gene variant confirming the diagnosis of X-linked AHC. The patient was eventually discharged home on hydrocortisone, fludrocortisone, and salt supplements. There are a few case reports of adrenal insufficiency in neonates with CDH, manifesting with symptoms before and immediately after reparative surgery. Clinical presentation of our patient was unique in manifesting as neonatal seizure secondary to severe hyponatremia after a stable postoperative phase. The patient’s electrolytes and hemodynamic status remained stable before, during, and after surgery for CDH. This case underlines the importance of taking detailed family history and continued vigilance for signs and symptoms of adrenal insufficiency in infants with repaired CDH by pediatricians and intensivists.
Right sided heart involvement in infective endocarditis in non drug addicts is rare.We report a case of isolated pulmonary valve endocarditis in a non drug addict male.
To compare the electrical activity of the diaphragm (Edi) of premature infants placed on continuous positive airway pressure (CPAP) with the Edi of premature infants placed on noninvasive neurally adjusted ventilatory assist (NIV NAVA). The secondary aim was to evaluate the feasibility of the use of NIV NAVA mode in the busy tertiary neonatal unit.This was a prospective crossover pilot study of premature infants requiring noninvasive respiratory support. Infants were randomized to initially receive either CPAP/biphasic (group 1) or NIV NAVA (group 2) and were then crossed over to the alternate group. Continuous Edi signals were recorded for 24 h, with 12 h each on CPAP/biphasic, and NIV NAVA along with other clinical and respiratory parameters. Results: Ten infants with a mean gestation age of 29 weeks (range 25-34 weeks) were enrolled, with a total cumulative Edi monitoring of 240 h. The average Edi peak on the biphasic/CPAP group (15.6 ± 7 mcV) was significantly higher (P < 0.005), compared to the Edi Peak on the NIV NAVA group (10.8 ± 3.3 mcV). The Edi min values were 3.23 ± 1.1 mcV, and 3.07 ± 0.5 mcV on CPAP/biphasic and NIV NAVA (P = 0.69) respectively. There were no significant differences in other clinical parameters between the two groups. No major adverse events were recorded during Edi catheter monitoring.The Edi peak values were significantly lower in NIV NAVA mode compared to CPAP/biphasic mode. The Edi catheter and NIV NAVA may also be used safely in premature infants.
To examine survival and outcomes in neonates who received therapeutic hypothermia (TH) for neonatal encephalopathy (NE) and extracorporeal membrane oxygenation (ECMO) versus ECMO alone.